Question/Problem - Cause
Causa
No power, no indication:
• The battery is faulty;
• The fuse is blown;
• Loose cable connection;
AC equipment does not work, red fault LED on:
• The connected AC equipment requires more than
150W. The inverter has switched off due to overload;
• AC equipment has a continuous power below 150W,
but the peak power is high causing the inverter to
shut down;
• The inverter has overheated due to poor ventilation
and switched off;
Solution
• Replace the battery;
• Check and replace the fuse;
• Check the connections;
• Reduce the electric load. Use a device with a power of
less than 150W;
• Use equipment with a peak power within the capacity
of the power inverter auto (300W);
• Unplug the inverter from the DC socket and let it cool
down for 15 minutes. Move the inverter to a cooler, more
ventilated place;