ATTENTION
Before cleaning vehicles, for example, always read the manufacturer's information, and if the surfaces can be washed
using high-pressure jets or if there is any restriction. In this case, do not use the pressure washer for this task.
Some general useful precautions are:
Never position the nozzle closer than 30cm away from the surface to be cleaned.
Never use the pressure washer to clean surfaces with loose, unprotected or fragile paint, or paint over loose elements etc.
Always keep the nozzle moving over the surface. Do not keep the jet at the same point for a too long period, because
it might damage the surface.
Note: when in doubt, check the information about the object or the surface to be cleaned with the manufacturer.
TURNING YOUR PRESSURE WASHER OFF AFTER USE
After using the pressure washer, follow the procedures below to turn off and disconnect the equipment:
1. Press the On/Off button (O) to turn the pressure washer off.
2. Close the water inlet flow regulator valve.
3. Discharge the water from the pump and hose by pulling the gun trigger (keep it pressed for some seconds until
water stops coming out through the nozzle).
4. Lock the trigger in the OFF position.
5. Disconnect the plug from the power outlet.
IMPORTANT
Always use the filter (sold separately (Figure 8.19)).
ELECTRICAL SAFETY
The Figure 8.20 shows a plug. For 2000W and 2600W models, the electrical network must have a ground
wire. For safety against electric shocks, use only the pressure washer in electrical installations with a 30 mA
residual current circuit breaker. If necessary, hire a reliable electrician and have this safety component installed.
FIGURE 8.20
9. PREVENTIVE MAINTENANCE
Wear appropriate "leather" gloves when performing maintenance or cleaning up the product in order to
avoid accidents with cutting edges.
Oil maintenance
1. The level of the oil must be chacked periodically;
2. Use only oil 15W/40;
3. The most important that the oil must be changed fater the first 50 hours of work and;
4. Successuvely every 100 hours or each 6 month (approximately 230ml or halfway through the oil mirror);
5. For access to oil entrance, disassemble the cover, releasing two lateral screws.
Painted or treated surfaces are subject to damages caused by the high-pressure washer.
Model
Voltage
Hidrolav 2950
220
Wire
Fuse/
Maximum distance
(minimum
Circuit breaker
to distribution box
section)
1,5mm
16 A
2
TABLE 8.1 – ELECTRICAL INSTALLATION
32
FIGURA 8.19
Extension cord up to
10 m (minimum gage)
21m
1,5mm
2
Extension cord up to
20 m (minimum gage)
2,5mm
2