Installation instructions
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC EN 60950-1 Ed2) or type ES1, PS1 (according to IEC EN 62368-1) for the main supply.
Main power supply:
Range: +7 Vdc to +28 Vdc
Max. consumption at 12 Vdc:
Screw terminal output: Use a multi-conductor shielded twisted pair cable.
Max. length RS485:
Wiegand / Clock & Data: 1 pair AWG24 – 98.4 ft max / 2 pairs AWG24 – 196.9 ft max / 3 pairs AWG24 – 328.1 ft max
Cable output (cable supplied): TRANXALARM - 14x0.22mm
Tearing is detected by an accelerometer.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
Touch screen read-only reader: if the bell is activated, contact J2 is used to connect the external ring (max. 200 mA at 28 Vdc).
Reader powered off. The default reader settings can be stored in internal memory accessible by UHF RFID technology. They will be taken into account when the reader is powered on.
R and S readers are configurable with the SCB configuration card or virtual configuration card created with SECard.
If the SCB is compatible with the reader's firmware, the LED lights green and the buzzer beeps five times.
If the SCB is not compatible with the reader's firmware, the LED lights red and the buzzer is activated for 1 s.
Caution: set your reader with your own company key.
On power-up, the reader enters an initialization phase:
1.
Activation of the white LED and buzzer for 100 ms.
For read-only readers:
2.
Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3.
For serial R/S ARC only: the orange LED flashes 20 times: waiting for an update.
4.
For ARCS Blue only: Activating white fixed LED during Bluetooth initialization.
5.
Activation of the default LED (flashes blue if no customer specific configuration).
6.
ARC Screen: display of the default image and keypad activation by touching the screen
For optimal operation, the biometric sensor must be free of all traces of water. Outdoors it is recommended to install the reader under cover.
The keypad is sensitive. Take off your gloves to enter your code.
For the ARC screen with an activated keypad, the default mode is: display the picture on standby and activate the keyboard by pressing the screen.
Caution: at the reader Bluetooth (BT1/BT2) powering, make sure that nothing is in an area of at least 10 cm / 3.94 in. around the reader (ex. No hand in front of
the reader...).
▪ The supply voltage at the reader's connector should be between +7 Vdc and +28 Vdc.
▪ As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level and the proximity of the
reader.
▪ Recommended distance between two readers: parallel plane: 15.8 in – same plane: 15.8 in – perpendicular plane: 11.8 in.
▪ Recommended distance between two Blue readers: 2 meters either plan.
▪ Readers installed on a metal surface may have reduced performances.
▪ Use a ferrite (two-way) for the cable (power supply and data). Example: reference 74271222 WURTH ELEKTRONIK.
▪ For ARCS screw terminal output reader, connect the 2.2 µF capa (provided) between +12V and GND directly to the output of the connector (no polarization).
▪ By design, the reader can be installed indoors and outdoors.
▪ Disconnect the wires or the connector of the reader BEFORE powering on or off.
▪ Operating temperature:
STid declares that the ARCS-X reader is compliant with the essential requirements of the Directives RED 2014/53/EU and RoHs 2011/65/EU. A copy of our declaration is available on
request from [email protected].
This device complies with Part 15 of the FCC rules and with ISED's license–exempt RSSs. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Note: the manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
This device complies with the safety requirements for RF exposure in accordance with RSS-102 issue 5 for conditions of use.
STid reserves the right to make change without notice, for the purpose of product improvement.
Typical: 12 Vdc
ARCS-A/PH5: 140 mA ARCS-C/PH5: 210 mA ARCS-E/PH5: 320 mA ARCS-I/BF5: 170 mA
ARCS-B/PH5: 170 mA ARCS-D/PH5: 290 mA ARCS-F/PH5: 360 mA ARCS-J/BF5: 200 mA
ARCS-A/BT1: 150 mA ARCS-C/BT1: 220 mA
ARCS-B/BT1: 180 mA ARCS-D/BT1: 300 mA
328.1 ft at 9600 baud
1 pair AWG20 – 164.0 ft max / 2 pairs AWG20 – 328.1 ft max
– length 10 ft.
2
UHF default configuration settings
Precautions for the biometric sensor and keypad
Readers A, B, C, I and J: -4 °F to 158 °F / -20°C à +70°C
Readers D, E and F: -14 °F to 122 °F / -10°C à +50°C
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1114A06- Page 2 sur 4 - Ed. 23/04/2019
ARCS / ARCS Blue
Lecteurs évolutifs
Notice d'installation
Power supply characteristics
ARCS-E/BT1: 330 mA ARCS-I/BT2: 180 mA
ARCS-F/BT1: 370 mA ARCS-J/BT2: 210 mA
Recommended cables
Anti-tearing
Bell
Read-only reader configuration
Powering-up the readers
Caution for Bluetooth reader
Precautions for installation
Declaration of compliance
ARCS / ARCS Blue
Lectores escalables
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
loading

Este manual también es adecuado para:

Arcs blue