The photocells are fitted with a transmitter that can be powered by two
3V6 2.7Ah lithium Thionyl chloride batteries or with an external 12/24V
AC/DC power supply, selectable with a jumper.
The optical unit (emitter diode + lens) of the transmitter and of the receiver
can be oriented in three different directions so it can be adapted to
different installation situations.
The photocell has two terminals for the connection of a free contact of an
external safety device (safety edge) and two terminals for the connection
of a resistive edge. The photocell is particularly suited for use on sliding
M
AIN TECHNICAL FEATURES
Power supply Transmitter
Power supply Receiver
Consumption Transmitter
Consumption Receiver
Container
Dimensions/weight
Protection rating
Infra-red wavelength
Relay contact range
Infra-red beam range
Operating temperature
Intervention time with triggering of photocell beam
Intervention time with triggering of safety edge connected to terminal
strip
Reset time
R
ECEIVER TERMINAL STRIP
1
+V
2
- V
3
N.C./N.A.
4
C
5 - 6
LOW BAT
T
RANSMITTER TERMINAL STRIP
1
+12 ÷ +24 V AC/DC
2
0 V
3 - 4
EDGE
5 - 6
EDGE 8K2
2 3,6V 2.7Ah Lithium Thionyl
chloride batteries
Alternatively 12 - 24 V AC/DC
12 -24 V AC/DC
< 500 μA
30 mA
ABS
110 x 50 x 25 mm 200g
IP 45
950 nm
0.5 A @ 24 V AC/DC
25m (in good weather conditions).
N.B.: Range may be reduced in
the presence of fog, rain, dust,
etc.
-20 +55° C
< 40 ms
< 60 ms
< 150 ms
Power supply 12 - 24 V AC/DC
Power supply 12 - 24 V AC/DC
Relay contact normally open or
closed depending on NO/NC
selection jumper
Relay contact normally open or
closed depending on NO/NC
selection jumper
Flat battery Normally open contact
Power supply 12 - 24 V AC/DC
Common power supply
Terminal for safety edge free contact
(jump if not used)
Terminal for 8K2 resistive edge
(DON'T jump if not used)
gates, mounted on the mobile part it can be connected to a wire or
resistive safety edge, without having to lay cables or use re-wind cables.
The battery life-span is more than 15 months.
This product can be connected to RIB control boards equipped with
autotest in compliance with Norm EN13849-1:2007. It can therefore
be used in order to create a system in compliance with the EN13241-
1:2003.
1 2 3 4 5 6
1 2 3 4 5 6




J2: Frequency Selection
J3: NO/NC contact
selection
RX
1 A
J1
Battery powered
J1
External Power supply
12/24V ac/dc
J1: Power supply selection
J2: Frequency Selection
TX
1 B