GUARANTEE
Our products are guaranteed for 12 months from the
delivery date. Our guarantee covers all parts that are
materially defective or that have manufacturing defects.
The guarantee will be considered void in the case of
insufcient maintenance and improper use.
The guarantee does not cover any parts not manufactured
by our company. Repairs must be made at our factory or by
personnel who we have authorized.
For all service the products must be sent by freight prepaid.
The labor expenses are not included in the guarantee.
Whenever you request a repair or replacement under
warranty, always inform us of the instrument's serial number
which is located on the adhesive label.
VERSIONS
· Compact with Short Nail for Standard and Turbo
Flow Flowmeters (cod. 00379016) 9V battery operated
with a short sinusoidal wave sensor with short nail.
(Fitting all owmeters except Mini owmeters and
those paired to 'Compact with projecting nail').
· Compact with Projecting Nail for Standard
Flowmeters (cod. 0037901C) 9V battery operated with a
short sinusoidal wave sensor with projecting nail.
(Fitting owmeters: ½" - 3" - 4" with Nylon body and ½"
- ¾" with stainless steel body).
· C o m p a c t f o r R a p i d C h e c k F l o w m e t e r s
(cod. RC379016) 9V battery operated with square wave
long sensor.
· Remote (cod. RE379016) 9V battery operated with
remote square wave sensor (60 cm. cable).
USE
Compact: installed directly on the owmeter.
Remote: remote connection with a turbine owmeter with
sinusoidal wave sensor.
Flow measurements of quantities of liquids obtained with
the Pony Flow 5 cannot be used to determine amounts or
commercial values for sale.
POWER SUPPLY
9 Volt battery (MN1604 6LR61).
Use only the type of battery indicated.
Do not throw dead batteries out in the environment but
dispose inside special containers. Dead batteries do not
have to be charged again.
INSTALLATION
Protected from the elements, from prolonged exposure
to sunlight, and from mechanical vibrations.
IMPORTANT: high pressure washing of the exterior of this
equipment could cause irreversible water damage to the
electronic components. To prevent any damage, remove the
display when washing the equipment's exterior.
The manufacturer declines all responsibilities for damage to
the display that is the result of operator negligence.
ASSEMBLY
Pony Flow 5 must be screwed on the body of the turbine
owmeter till the bottom, without forcing. Once this
operation is done, the instrument can be 270° turned till
achievement of the wished position and its lower part can
be xed by means of the two screws situated in proximity
to the sensor.
GENERAL FEATURES
a) The instrument is turned on by the pressure of any keys
or by the passage of ow;
b) The display will turn off against closure of the door or
automatically , once the time set in the Setting Menu
under "Extinction Time" is passed.
c) Back lighting of the display, activated only under no
light , turn off automatically when the door is closed
or automatically, once the time set in the Setting Menu
under "Lighting Time" is passed;
If the maximum value (600) is set on "Lighting Time"
and there is ow, back lighting stay always active.
d) Multifunction Display, with visualization at the same time
of partial units (FLOW), total resettable units (PARTIAL)
and total non resettable units (TOTAL).
e) Its capacity of counting total resettable units (PARTIAL)
is 4.294.967 lt., or 4.294,9 cbm/h or 1.134,734 USA
gallons. Once the limit is reached, calculation starts again
from zero "0".
f) Its capacity of counting total non resettable units
(TOTAL) is 4.294.967 lt., or 4.294,9 cbm/h, or 1.134.734
USA gallons. Once the limit is reached, calculation starts
again from zero "0".
g) Possibility of setting up to 6.553,5 pulses per liter.
h) Reading Menu and Setting Menu.
i) Set Impositions are always stored.
j) Units calculation is also allowed with the protection door
closed.
k) Possibility of setting the reading of units with or without
decimals (max. 2 decimals).
l) In the Setting Menu (2 pages) the following values can
be selected: