SENSITIVITY switch adjusts the input
(17)
sensitivity versus the amplifier's rated
output power. Choose between 0.77 V,
26 dB and 1.4 V settings. If using multiple
KM amps, choose the 26 dB setting for equal
output from all amplifiers.
INPUTS accept line-level input signals
(18)
using balanced XLR, balanced ¼" TRS,
or unbalanced ¼" TS connectors.
RCA INPUTS (KM750 only) accept
(19)
unbalanced line-level signals using
RCA connectors.
BREAKER (automated fuse,
(20)
KM1700 only). After eliminating the cause
of faulty operation, simply depress the
BREAKER and power up the unit again.
The BREAKER acts in place of common
discardable fuses.
BREAKER WARNING: Take the following actions
BEFORE resetting the breaker:
• Unplug the AC main cable
• Move the POWER switch to the "OFF" position
• Turn all input gain control elements down
• And then, reset the breaker, connect the unit to
the mains, switch ON and slowly increase the
gain to the target volume
17