To clean or replace the filter:
A. Release the line pressure and
dismount the METER in compliance
with the instructions given in paragraph
E2.
B. Unscrew the 1/2_ nut and remove
the filtering disk.
C. Properly clean the filter or use a
new filter (see Spare parts list in
paragraph M3).
D. Place the filter again, paying
attention to components' positioning.
L Product identification
Some technical data of
the METER, which is
essential for its safe
use, is indicated on the
CE plate located on the
right side of the handle.
36
gasket
Nut
Warning
- Do not use filters which have
been damaged during improper
dismounting or cleaning
operations.
- Always reposition the filter with
the utmost care.
If the filter is in good condition
and is correctly installed, it
guarantees the good operation
of the METER, thus avoiding any
dust or foreign bodies, which
may lock or damage the METER
valve.
E. Reassemble the METER
according to the instructions given in
paragraph E6.
F. Fix the connection again and
tighten it at 20 Nm.
Nylon ring
MODEL METER
Max Work. Pres. 7000 KPa (1015 PSI)
Operating Temp. -5/+50°C (+23/+122 °F)
Min Flow Rate 1 L/m (0.26 gpm)
Max Flow Rate 30 L/m (7.9 gpm)