Do not use object with edges and corners, and cutting tools to knock or scratch the surface of bathtub.
Check the power line often to make sure the switch and plug are good.
Check the flow pipe and drain pipe often to make sure no water drops and bailing smoothly.
6. TROUBLES SHOOTING
Before attempting to check any problem, make sure the electricity supply is off.
Trouble
Cause
The water pressure is abnormal.
Switch is not connected well
No pressure or
Low flow
The flow pipe is broken
Filter of hot and cold switch jammed
Chemical cause, such as gas, glue
Electroplate goes
moldy
Stuffiness and humidity change
There is malfunction in pump
Screw for pump too loose or too tight
Big noise
There is deck on pump
No power input or Low Voltage
Motor is defective
Pump doesn't start
The tube connected to the bath and
pump's air switch has been brush off.
Pump's air switch is defective
Pump is not filled with liquid
Suction or discharge pipe is blocked
by impurities
Pump runs but no
Pump is not installed at correct level
water
in relation to the spa suction
Water level is too low
Thermal overload switch in motor or
Pump stops during
external motor protection cuts off
operation
Control Circuit has cut out
Disposal
Check the water pressure in flow pipe
Check the switch and connect well
Change the pipe
Clean the filter
Change it and keep away from chemical
Keep dryness and ventilation
Change the pump
Adjust the screw
Check the pump, keep the deck away from
pump
Check circuitry
Replace pump
Reconnected the tube
Replacing air switch
Restart while filled
Check pump or pipeline
Confirm correct installation with the installer
Ensure water lever in at least 50mm above the
lever of jets
Check motor cooling and ensure adequate
ventilation; motor is operating with low voltage
supply
Turn on the circuitry.
14