Technical data
Description
Voltage and Frequency
Current
Flow Rate
Maximum Depth
Maximum Height / Maximum
Manometric Height Value
Power Cable
Outlet Diameter
Duty cycle
Conductors
Insulating & IP Grade
WARNING
To prevent power discharge or serious accident if the power cable gets damaged make it replaced by
the manufacturer or in a
spills or splashing while operating. Do not expose to rain, liquids and / or humidity.
Before gaining access to terminals, all power circuits should be disconnected.
WARNING
Power Requirements
WARNING
The tool shall be grounded while in use to prevent an electric shock.
• Connect the plug into a correctly grounded power outlet, as shown in Figure A.
Not all the power outlets are correctly grounded. If you do not know for sure
verify with a qualified electrician.
• If the plug destined for the tool is a two-prong (two orifices), FOR NOT
REASON AT ALL REMOVE OR ALTER THE GROUND CONDUCTOR SET IN THE
PLUG. Use a temporary adapter as shown in Figure B and always connect the
ground ring as indicated.
When using an extension cable, verify the gauge is enough for
CAUTION
the power that your product needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and overheating. The following table shows
the right size to use depending on cable's length and the ampere capability
shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
labeled "For Outdoors Use". These extensions are especially designed for operating outdoors and reduce
the risk of electric shock.
WARNING
All wiring, electrical connections and system grounding must comply with
MEXICAN OFFICIAL NOM-001-SEDE-2012, ELECTRICAL INSTALLATIONS or any local codes and
ordinances. You must use a qualified electrician.
BOS-1/2LH
Code
100169
6 A
Power
1/2 Hp
Speed
1902 gal/h
65.61'
50 minutes work per 20 minutes idle. Maximum 6 hours per day.
16 AWG x 3 C with insulating
Authorized Service Center. Power insulation in this tool is affected by liquid
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
BOS-3/4LH
100170
Iron Cast Submersible Pump
127 V
7.7 A
3/4 Hp
3 500 RPM
1981 gal/h
16.4'
82'
32.8'
1"
temperature of 221 °F
Class I
Power cord grips used in this product: Type "Y".
Build quality: Basic insulation
Thermal insulation on motor winding: Class B
Extension gauge
from 6 ft to 49 ft
18 AWG( * )
16 AWG
14 AWG
8 AWG
BOS-1LH
100171
60 Hz
9.6 A
1 Hp
2219 gal/h
98.42'
14 AWG x 3 C with insulating
temperature of 221 °F
IPX8
WARNING
|
higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
grounded extension cable
ENGLISH
A
B
3