GENERAL
Centrifugal pumps, when properly installed and when
given reasonable care and maintenance, should operate
satisfactorily. The following paragraphs discuss the
general principles that must be considered to ensure
trouble free pump operation.
INSPECT THE SHIPMENT
All pumps are tested, crated and inspected to ensure their
arrival in good condition. Occasionally, products may
become damaged during shipment. When the pump is
received, examine it closely to make sure there is no
damage or broken parts. If damage is evident, then report
this fact immediately to either the carrier that made the
shipment or the dealer from which pump was purchased.
LOCATION OF UNIT
The pump should be as near the liquid source as practical
so that a short, direct suction pipe may be used. A short,
direct discharge pipe, with the least number of elbows and
fi ttings, should be used to minimize head loss. If practical,
it should be placed so that it will be accessible for
inspection during operation. Head room should be
provided where it is necessary to use lifting devices. The
equipment selected should be compatible with the
environment. Pumps and motors should be protected
against fl ooding.
FOUNDATION
The foundation should be suffi cient to absorb vibration
and to form a permanent, rigid support for the close
coupled pump. A concrete foundation on a solid base
should be satisfactory. Foundation bolts of the proper size
should be embedded in the concrete.
END SUCTION
CENTRIFUGAL PUMPS
OWNER'S MANUAL
READ AND FOLLOW SAFETY INSTRUCTIONS
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one
of the following signal words and be alert to the potential
for personal injury:
D A N G E R
personal injury, death or major property damage if
ignored.
W A R N I N G
personal injury, death or major property damage if
ignored.
C A U T I O N
hazards that will or can cause
minor personal injury or major
property damage if ignored.
The label NOTICE indicates
special instructions, which are
important but not related to
hazards.
Carefully read and follow
all safety instructions in
this manual and on pump.
Keep safety labels in good
condition.
Replace missing or damaged
safety labels.
Wire motor for correct voltage.
See motor nameplate.
Ground motor before connecting to power supply.
RECORDING MODEL & SERIAL NUMBERS
Please record the model and serial number for your
Franklin Electric pump. These numbers will be needed
when ordering parts for repair.
Pump Model:
Motor Model No.:
Motor Model Mfr.:
INSTALLATION OF CLOSE COUPLED PUMPS
Enough clearance should be provided at the rear of the
motor so that it, and the bracket-impeller assembly, can
be removed from the pump casing for servicing.
The unit is to be positioned and bolted to the foundation or
bedplate so that no piping strain is exerted on the suction
and discharge connections. Shim where necessary under
the mounting feet of the close coupled pumps so that the
warns about hazards that will cause serious
warns about hazards that can cause serious
warns about
W A R N I N G
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
Tabla de contenido
loading

Resumen de contenidos para Franklin Electric D Serie

  • Página 9: Bombas Centrífugas De La Serie D - Succión Axial

    Sírvase anotar el modelo y los sea posible, de modo de que se pueda usar una tubería de números de serie de su bomba Franklin Electric. Deberá succión en un tramo corto y directo. Se debe tender una tubería tenerlos a mano cuando tenga que pedir piezas de repuesto.
  • Página 10 las bombas de acoplamiento corto, según se requiera, para Se debe instalar una válvula de compuerta en la línea de nivelar la unidad. Apriete bien y de manera uniforme los pernos descarga. Ésta ayudará a cebar la bomba y permitirá darle de montaje que fi...
  • Página 11: Lubricación - Bomba

    Verifi que la rotación de los motores trifásicos encendiendo LUBRICACIÓN - MOTORES brevemente el motor, para que la bomba dé sólo unas cuantas Generalmente, los motores vienen con cojinetes sellados que no vueltas (el funcionamiento prolongado en el sentido incorrecto requieren de mayor lubricación.
  • Página 12: Bombas Com Motores De Bastidor Jm

    FIGURA 1 - VISTA TRANSVERSAL DE LA BOMBA Ahora, la unidad giratoria del sello mecánico (4) se puede sacar de la camisa del eje (5), o se pueden sacar juntos del motor la CON BASTIDOR DE MOTOR 56C unidad giratoria del sello mecánico (4) y la camisa del eje (5). Hale el asiento cerámico del sello y el asiento acopado para sacarlos del soporte (3).
  • Página 13: Piezas De Repuesto

    oriendada hacia el sello cerámico del soporte. Tenga mucho PRESIÓN INSUFICIENTE cuidado cuando deslice la parte de caucho del sello sobre el eje. Se puede deber a lo siguiente: Se puede aplicar mayor fuerza sobre la superfi cie de caucho si La altura manométrica del sistema es menor de lo esperado se usa un manguito que calce sobre el eje y que repose El líquido tiene aire o gas...
  • Página 16 Franklin Electric Co., Inc. Franklin Electric Co., Inc. garantiza que, por el lapso de 1 año desde la fecha de instalación, o de 2 años desde la fecha de fabricación, lo que ocurra primero, sus productos nuevos no tienen defectos de materiales ni de mano de obra CUANDO se instalan en un sistema de aguas blancas y se usan únicamente para bombear agua potable.

Este manual también es adecuado para:

Da1aDa1bDb1Db1-1/2Db2-dc2Dc1-1/2 ... Mostrar todo

Tabla de contenido