Grohe Europlus 33 170 Instrucciones De Montaje página 4

Ocultar thumbs Ver también para Europlus 33 170:
Idiomas disponibles

Idiomas disponibles

974991.book : i97499us.fm Seite 1 Dienstag, Mai 25, 1999 3:54 PM
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
9.5 L/min or 2.5 gpm/80 psi
8.3 L/min or 2.2 gpm/60 psi
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
- handle rotation stop available,
(order no. 46 308)
• Water connection
• Non reversible cartridge
Note
Major pressure differences between hot and cold
water supply should be avoided.
Installation
Flush pipes thoroughly.
Mount faucet on basin
See dimensional drawing fold-out page I.
For installation you require only a 13mm (1/2'') socket
wrench, see fold-out page III, fig. [1].
Connect faucet
For this purpose the supply hoses must be connected
to the angle stops (or other supply points), see figs. [1]
and [2].
The hot water supply should be connected on the left,
the cold water supply on the right side.
Avoid cross connection. The cartridge is not
reversible.
Fit pop-up drain (28 957), see fold-out page II, ensure
that flange of pop-up drain is sealed.
1
English
Open angle stops and check faucet for correct
function, see fig. [3].
Lift lever
Press lever down
Move lever to right
Move lever to left
Check connections for leakage.
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combina-
7.25 psi
tion with hydraulic instantaneous water
14.5 - 72.5 psi
heaters is not recommended.
Please proceed as follows to limit flow:
1. Strip lever lower part (A), see fig. [4].
145 psi
2. Loosen set screw (B) using a 3mm (1/8'') socket
232 psi
spanner, see fig. [5].
3. Pull off lever (C).
176 °F
4. Unscrew cap (D).
5. Change flow rate by turning hexagon socket screw
clockwise with a 1.5mm socket spanner. Turn clock-
hot - LH
wise (to reduce flow) or anticlockwise (to increase
cold - RH
flow), see fig. [6].
Assemble in reserve order.
Maintenance
I. Cartridge, see fig. [5].
1. Shut off the hot and cold water supply!
2. Strip lever lower part (A).
3. Loosen set screw (B) using a 3mm (1/8'') socket
spanner.
4. Pull off lever (C).
5. Unscrew cap (D).
6. Remove screws (E) and detach complete
cartridge (G).
7. Change either the complete cartridge (G) or
seals (G1).
Assemble in reserve order.
Make sure that the cartridge seals (G1) engage in the
grooves on the housing. Fit screws (E) and tighten
evenly and alternately.
II. Flow regulator, see fold-out page II.
Unscrew and clean flow regulator (13 955).
Assemble in reverse order.
Inspect and clean all parts, replace as necessary and
grease with special grease (order no. 18 012).
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this single lever faucet will be
found in the Limited Warranty supplement.
= open (water flow)
= closed (off)
= cold water
= hot water
loading