security
Made in Italy
BT2014/35/UE
EMC2014/30/UE
Adjustable sensitiveness
Anti-opening protection tamper
Anti-shock piezoelectric sensor
White color
Installation on wall or on glass
Nominal supply voltage 12Vcc ±10%
Maximum input 10mA
Coverage 1,5mt (cement) ÷ 3,5mt (glass, wood, steel)
Alarm output NC
ABS External container
Functioning temperature +5°C ÷ 40°C
Safety degree: 1
Ambiental class: 2
Dimensions(LxAxP) 77x26x21mm
Approved directives CEI EN 50131-1
INSTALLATION
Fasten firmly the sensor vertically to the surface.(If the C70S
in atmospheres is settled in which it can be taken place of
condenses, it is opportune to mount the sensor with the
hole for the income of cables turned towards the bottom).
Check making sure that the base adheres perfectly. In this
way the vibrations reach the piezoelectric sensor without
being attenuated by interposed materials.
Use the two pre-marked holes to screw the sensor base if the
surface allows it or use an appropriated adhesive.
Remove the jmp jumper to use the impulse-counter function
with which the sensor requests to detect a vibration of greater
amplitude and/or greater duration before detecting an alarm.
Position the circuit letting the three holes match to the pins
found on the base.
Perform the electric connection, adjust the trimmer for a
medium sensitivity and close the cover tightening the central
screw.
Signalling
LED alarm
Trimmer
adjustable
sensitivity
OPERATION TEST
Test the sensor operation to check the exact sensitiveness adjustment :
The sensor shall detect an alarm with a decisive stress, typical of shocks aimed to demolish the surface to protect, but has to be insensible to
minor stresses.
Adjust the sensitiveness trimmer for subsequent approximations paying attention to close the container before carrying out the test.
2
Lead free
Pb
RoHS
compliant
JMP
+
Piezoelecrtic
sensor
To remove the Jumper for
activation impulse - counter function
Electronic sensor shock detector, 12V contact N.C
Example of wall installation