Eaton 5S 550 Manual Del Usuario página 7

Ocultar thumbs Ver también para 5S 550:
1. Operating conditions
• This product is an Uninterruptible Power Supply (UPS) for computers and their peripherals, television sets, stereo systems and video
recorders... It must not be used to supply other electrical equipment (lighting, heating, household appliances, etc.).
2. UPS connections
• Connect the UPS 1 to the AC-power system via a wall outlet with an earth connector, using the input cord of your computer
(see
• Plug critical equipment (computer, monitor, modem, etc.) into the outlets 9 providing battery backup power and surge protection
(see
rated
• Other devices (printer, scanner, fax, etc.) can be connect to the surge protection outlets 8
The
Optional Internet modem / Network connection:
A modem or Ethernet data line can be protected against surges by connecting it via the UPS. Connect the existing device cable between the
wall outlet and the UPS, and use a similar cable between the UPS and the device, as indicated in figure
supplied).
Optional USB connection:
The UPS device can be connected to the computer using the USB cable 4
Eaton UPS Companion software is downloadable from powerquality.eaton.com. Register for the
warranty on powerquality.eaton.com.
3. Operation
• Battery charge: The UPS charges the battery as soon as it is connected to the AC outlet, whether button 12 is pressed or not.
When
only
charged
to ensure the best possible performance.
• Switching-on the UPS: press button 12 for about 1 second.
• Surge protection outlets 8 without battery backup: Equipment connected to these outlets is supplied as soon as the input AC cord is plugged
in. They are not affected by button 12.
• Battery backup outlets 9 : Equipment connected to these outlets is supplied as soon as button 12 turns green (see
These
UPS is not connected to AC power (button 12
• AC-power disturbance: If AC power is disturbed or fails, the UPS continues to operate on battery power. Button 12
green. In normal mode, the audible alarm beeps every ten seconds, then every three seconds when the end of battery backup time is
near. In silent mode, the audible alarm simply beeps once when the UPS transfers to battery power.
• If the power outage lasts longer than the battery backup time, the UPS shuts down and automatically restarts when power is restored.
Following a complete discharge, a few hours are required to recharge the battery back to full backup time.
• Surge protection: All outlets include surge protection.
Troubleshooting (For further information, visit the www.powerquality.eaton.com site or contact after-sales support.)
Problem
1
The battery backup outlets 9
are not supplied with power.
2
The connected devices are not
supplied when AC power fails.
3
AC power is available, but the UPS
equipment and operates on battery power.
overload on the UPS output.
4
Green button 12 and red LED 11 are •
audible alarm beeps every 2 are overloaded. connected to the battery backup outlets seconds.
614-06822-00
figure
A).
figure
C),
taking
current
indicated
in
surge
protection outlets are not backed up by battery power in the event of a power outage.
used
for
the
provide
its
maximum
for
8
hours. It is recommended that the UPS be permanently connected to the AC power supply
outlets
can
be
Diagnostic
Button 12 is not lighted on.
to the battery backup outlets 9 .
the corresponding button.
care
not
amperes.
first
time,
performance after
turned
on
flashes).
The devices are not connected
Circuit breaker 13, located at the rear •
of the UPS, has been tripped by an
The UPS battery backup outlets 9 •
to
exceed
the
(see
figure
C).
B
(cable
supplied
(see
figure
the
battery
will
it
has
been
figure
even
if
the
flashes
Solution
Press button 12 and check that it
turns green.
Connect the devices to the
battery backup outlets 9 .
Disconnect excess
reset the circuit breaker 13 by pressing
Disconnect excess equipment on and
not
B).
D).
7
loading

Este manual también es adecuado para:

5s 7005s 10005s 1500