ELECTRIC SHOCK CAUSED BY LIVE PARTS
•
Disconnect the mains voltage supply before performing the work and ensure
that it cannot be switched on.
•
Verify that no hazards can be caused by electrically conductive objects or
media.
Failure to follow these instructions will result in death or serious injury.
SUPPLY VOLTAGE FLUCTUATIONS
The pump electronics can be damaged by voltage fluctuations.
•
Verify that the pump is not controlled via an external speed controller which
changes the supply voltage.
•
Verify that the pump is controlled with 230 V without phase angle control.
•
Switch the pump on and off via the controller.
Failure to follow these instructions can result in equipment damage.
1. Connect the circulation pump in accordance with the instructions of the
manufacturer.
2. Route the connection cable of the circulation pump through the cable duct
to the bottom and connect it to the solar controller.
- Observe the operating instructions of the solar controller.
Use a shielded cable 3 x 1.5 mm² and up to Ø 10 mm to extend the connec-
tion cable.
Mounting
DANGER
NOTICE
PrimoSol® 130
EN
16