WIRING DIAGRAM FOR LOW CLEARANCE CEILING RECESS KIT
(FOR USE WITH 2 HEATERS ON/OFF OR DIMMER)
BELOW IS A SIMPLIFIED DIAGRAM OF THE TERMINAL BOX.
ALL CONNECTIONS ADJUSTED BY THE INSTALLER ARE DISPLAYED.
ITEMS NOT DISPLAYED SHALL NOT BE MODIFIED.
Output 1
ON/OFF Power (Load)
WARNING
AC Single Phase Heater
must be permanently
installed and hard wired
by an authorised/licensed
person.
This product is designed for use
with both 220-240V & 208V
Platinum Electric Heaters.
NOTES:
• For wiring instructions using Bromic SmartHeat Electric Wireless Dimmer BH3130011-1 or
ON/OFF Controller BH3130010-1 refer to the instructions provided with the controller.
• Connecting to a 3-phase power system can only be done for 208V versions of the
Platinum Electric Heater.
• *The junction box and connections inside must be suitable for the voltage and current
capacity of the heaters being installed.
HEATER
CABLE 1
S2
N2
L
S1
N
ON/OFF Power Supply
OR
OR
OR
OR
WIRES
DENOTED BY
DASHED LINES
ARE SUPPLIED
BY THE
INSTALLER.
ON/OFF Power (Load)
Input
BROWN
BLUE
LIVE/ACTIVE
NEUTRAL
HOT LEG 1
HOT LEG 2
PHASE A
PHASE B
PHASE B
PHASE C
PHASE C
PHASE A
bromic.com
S2
N2
S1
Output 2
JUNCTION
BOX*
SUPPLY
GREEN/
YELLOW
EARTH
HEATER
CABLE 2
L
N
13