Troubleshooting - Clarke BextSpot Pro Spotter Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

BASIC TROUBLESHOOTING
PROBLEM
CAUSE
Not plugged in to power source
Faulty power cable
Machine
doesn't work
Faulty extension power cable
Building circuit breaker tripped
Vacuum /pump switch not on
Vacuum /pump switch faulty
Faulty solenoid
Solution pump
Faulty solution pump
not working
Pump overheated
Loose or broken wiring
Vacuum /pump switch not on
Vacuum /pump switch faulty
Vacuum motor thermal overload tripped
Vacuum motor
not working
Faulty vacuum motor
Worn carbon brushes
Loose or broken wiring
Air leaking around recovery gasket
Vacuum gasket damaged or worn
Loose vacuum hose connections
Poor pick up
Defective vacuum hose
Loose vacuum hose cuffs
Vacuum hose clogged
Solution tank is empty or low
Vacuum /pump switch not on
Dirty or plugged spray tips
Improper spray tip size or spray angle
Uneven or no
solution spray
Worn spray tips
Faulty solution pump
Clogged solution tank fi lter
Pinched or kinked solution hose
2/14
INSTRUCTIONS FOR USE
SOLUTION
Plug into a grounded outlet
Contact Distributor
Replace with new extension power cable
Reset circuit breaker
Turn on switch
Contact Distributor
Contact Distributor
Contact Distributor
Determine cause and allow 30 minutes for pump to cool
Contact Distributor
Turn on switch
Contact Distributor
Check for obstruction and allow 30 minutes to cool
Contact Distributor
Contact Distributor
Contact Distributor
Ensure recovery lid is fi rmly tightened
Replace gasket
Ensure vacuum hose connections are tight
Replace vacuum hose
Ensure cuffs are secure to the housing
Remove obstruction from vacuum hose
Fill solution tank
Turn on switch
Clean or replace spray tips
Contact Distributor
Contact Distributor
Contact Distributor
Clean or replace fi lter
Check for obstructions and kinks and reroute or replace if
needed
56091115 - BextSpot Pro
ENGLISH - A
A - 7
Tabla de contenido
loading

Este manual también es adecuado para:

Clarke130sp

Tabla de contenido