Boom Mount
1. Fix the Boom in the ceiling.
2. To ensure safety, install first
the anti-fall ropes.
2
Must attach
3. Attach the Boom with GSC3506 ceiling hole
and rotate to fix it in place.
4
1 1
Boom (not provided)
Note: The anti-fall rope diameter must
be less than 5mm, and the pulling force
must be greater than 25kgf.
3
4. Plug in the Ethernet and 2-pin
cables.
~5~
POWERING AND CONNECTING GSC3506
GSC3506 can be powered on using PoE/PoE+
switch or PoE injector using following steps:
Step 1: Plug a RJ45 Ethernet cable into the
network port of the GSC3506.
Step 2: Plug the other end into the power over
Ethernet (PoE) switch or PoE injector.
Note: It is recommended to use PoE+ power supply
to achieve the best audio effect.
Connecting Wiring Seat
GSC3506 supports to connect a "Normal Key"
to 2-pin port via Wiring Seat.
Step 1: Take the wiring seat from the install kits.
Step 2: Connect the Normal Key with the wiring
seat (as shown in the illustration on the right).
ACCESSING THE CONFIGURATION INTERFACE
A computer connected to the same network as the GSC3506 can discover and
access its configuration interface using its MAC address :
1. Locate the MAC address on the MAC tag of the unit, which is on the underside
of the device, or on the package.
2. From a computer connected to same network as the GSC3506, type in the
following address using the GSC3506's MAC address on your browser: http://
gsc_<mac>.local
Example: if a GSC3506 has the MAC address C0:74:AD:11:22:33, this unit can
be accessed by typing http://gsc_c074ad112233.local on the browser.
For more information, please refer to GSC3506
User Manual at:
https://www.grandstream.com/support
RJ45 Ethernet cable to
Network Port
Power over Ethernet (PoE)
Switch or PoE injector.
Wiring Seat
2-pin Port
Normal key