V2 WALLY-R Manual Del Usuario página 5

Idiomas disponibles
  • ES

Idiomas disponibles

RELAY CONTACT
The four output relay contacts are normally open type; it is
possible to change it as normally closed type. Refering to fig. 1
connect point A with point B and cut the trace at point C (Fig.1).
WARNING! IF THE RECEIVER IS SUPPLIED BY 24 VAC-VDC,
DO NOT ACTIVE MORE THAN 2 RELAYS SIMULTANEOUSLY
TECHNICAL DATA
Power supply
12 Vac/dc (DIP 1 ON) / 24 Vac/dc (DIP 1 OFF)
Relay contacts
1A / 30Vdc
Temperature
-20 ÷ +60°C
Consumption
17mA stand by
Sensibility
≥ -103 dBm
S/N
> 17dB @ 100dBm m=100%
Size
132 x 26 x 74 mm
Protection degree IP55
IMPORTANT REMARKS
"This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation."
"Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment."
99/05/CE DIRECTIVE CONFORMITY
The WALLY-R are in conformity with the provisions of the
following EC directive(s) (including all applicable amendments)
and that the standards referenced here below:
EN 60950-1, EN 301 489-1, EN 301 489-3, EN 300 220-3
Racconigi, 12/01/2010
V2 SPA legal representative
Cosimo De Falco
loading