6.2 Advanced menu:
MENU
First coupling between Bluetooth device and control unit
Electrical brake activation time
.
.

0 = disabled
1 - 100= enabled
Functioning of PHOTO1 moving from closed
.
.

0 = Check PHOTO1
1 = The gate opens also with PHOTO1 busy
Functioning of PHOTO2
.
.

0 = Enabled in opening and closing OP/CL
1 = Enabled only in opening OP
Photocells test
0 = disabled
.
.

1 = enabled PHOTO1
2 = enabled PHOTO2
3 = enabled PHOTO1 and PHOTO2
Safety edge type
.
.

0 = contact (NC)
1 = resistive (8k2)
Operation mode of safety edge
0= working only in closing with inversion of movement
.
.

1 = stops the automation (both opening and closing) and free the obstacle (short
inversion)
Safety edge test
.
.

0 = disabled
1 = enabled
.
.

Partial opening
.
.

Auto reclosing time from partial opening (0 = disabled)
Blinker output mode
.
.

0 = Fix
1 = Blinking
.
.

Pre-flashing time (0 = disabled)
Courtesy ligth settings
0 = At the end of movement for a TCY time
1 = On if the gate is not closed + TCY time
.
.

2 = On if courtesy light timer (TCY) not expired
3 = Open gate light on/off
4 = Open gate light with proportional flashing
.
.

Courtesy light time
Dead-man
.
.

0 = disabled
1 = enabled
Setting threshold of cycles for assistance request. Once limit is reached the next
.
.

cycles will be done with fast blinking (only if  enabled) (0 = disabled)
Continuous blinking for assistance request (done only with closed gate).
.
.

0 = disabled
1 = enabled
Viewing of the memory location for a single transmitter
Cancellation of a single transmitter
Restore defaul settings, enter to modify the parameter and then keep pressed the
.
.

MENU button, a count down appears that ends with  on the display
Cancelling all transmitters, enter to modify the parameter and then keep pressed
.
.

the MENU button, a count down appears that ends with  on the display
6-1622241
rev.8
12/09/2022
DESCRIPTION
ITA
ENG
FRA
SELECTABLE
ESP
DEU
POR
VALUES
DEFAULT
min-max
0-100
0
0-1
1
0-1
0
0-3
0
0-1
0
0-1
0
0-1
0
0-100
30
0-900
20
0-1
1
0-10
0
0-4
0
0-900
0
0-1
0
0-100
0
0-1
0
0-999
0-999
UNITS
x0.01 s
%
s
s
s
x1000
cicli
7 / 12