Metz SCA 3083-M2 digital Manual De Instrucciones página 30

Idiomas disponibles

Idiomas disponibles

controller (master). If the metering system deter-
mines that the flash fired by the master within this
brief period was sufficient for a correct exposure of
the subject then the slave unit will not be triggered.
Possible remedy:
• Reduce the ambient light (e.g. darken the room).
• Set a higher f-number on the camera (e.g. f/5.6
instead of f/2).
• Use a neutral density filter in front of the lens.
• Use a lower light sensitivity.
Problem:
The mecablitz 40 MZ-3 has been equipped with
the slave adapter. But the LC display does not
change to "SL" slave mode after the flash unit has
been switched on.
Possible cause:
The secondary reflector of the mecablitz is activated.
Remedy:
Switch off the secondary reflector of the mecablitz.
Problem:
The mecablitz 54 MZ-3/4 has been fitted with the
slave adapter but it not ready for firing after is has
been switched on, even though the batteries are
fully charged.
Possible cause:
The secondary reflector of the mecablitz is activated.
Remedy:
Switch off the secondary reflector of the mecablitz.
30
loading