14.18 Minimum temperature limitation
Heating with ambient temperature setpoint:
The minimum threshold is preset to 7°C; it can be changed from
- 7°C to 15°C, with 1°C intervals.
Heating with surface temperature setpoint: The minimum
threshold is preset to 20°C; it can be changed from -20°C to
40°C, with 5°C intervals. To change the minimum threshold,
press
or
and confirm by pressing
want make any changes, press
suggests to set the maximum threshold. To confirm and close
the settings, press 2x
.
Ambient
temperature
control
14.19 Ambient temperature limitation
The maximum threshold is preset to 30°C; it can be changed
from 19°C to 30°C, with 1°C intervals. Press
display the desired value. To confirm and move to the next
setting, press
. To confirm and close the settings, press 2x
.
1
14.20 Surface temperature limitation
The maximum threshold is preset to 80°C; it can be changed
from 40°C to "no", with 5°C intervals. Press
display the desired value. To confirm and move to the next
setting, press
. To confirm and close the settings, press 2x
.
. If you do not
: the device automatically
Superficial
temperature
control
or
to
2
or
to
- 32 -
2
If "no" is selected, the control will not take the surface
temperature limitation into account.
14.21 Maximum Boost duration
The maximum Boost duration is preset to 60 minutes. It is
possible to change it from 30 to 90 minutes, with 30-minute
intervals.
The Boost symbol and heating indicator are displayed and the
set duration of 60 minutes flashes. Press
the desired duration. To confirm and move to the next setting,
press
. To confirm and close the settings, press 2x
1
or
to display
.
Code 1910000000358 - nv02