FONESTAR MOV-6060L Manual De Instrucciones página 6

EN
To interconnect them, you must use XLR cables with the following configuration:
IMPORTANT: the complete length of cable used to interconnect the devices in a line must not exceed 100
meters. To prevent line interference, it is recommended that an electric terminator consisting of a 120 Ω
resistor be placed at the last element in the chain between pins 2 and 3 of the XLR DMX OUT connector of
the last element.
- - Connect all the elements to the power supply and turn them on to start using them.
MASTER-SLAVE CONTROL ("MASTER-SLAVE")
The master-slave function allows several lights to operate in synch (the same colour and the same
movements) without the need of a DMX controller.
- All lights must be interconnected to work in this way.
- No particular mode should be selected on the lights that you wish to comply with the main or "MASTER"
light. These lights are called SLAVE lights.
- At the MASTER light, select any of the operating modes.
SECURITY RECOMMENDATIONS
- Do not under any circumstances access the internal parts of the device.
- Make sure that the device is at least 50 cm away from flammable substances or elements.
- Looking at the rays from any distance less that 15 cm can cause serious damage to the eyes, as can direct
exposure to radiation for more than 10 seconds.
- Continuously switching the unit on and off will result in a decreased life span of the unit.
- These devices should only be used in areas that are refrigerated and under cover.
- Do not move or handle the appliance while it is connected to the mains and in operation.
- Do not modify the lighting elements of the device without technical supervision or with any materials that
are not approved by the supplier
.
- 6 -
loading