en
10
Type
Order number
Battery charging voltage (automatic voltage detection)
A)
Charging current
Permissible battery temperature during charging
CORE18V... batteries:
Charging duration at battery capacity, approx.
– 4.0 Ah
– 8.0 Ah
– 12.0 Ah
Standard batteries:
Charging duration at battery capacity, approx.
– 2.0 Ah
Amount of battery cells
Weight according to EPTA-Procedure 01
Class of protection
A) Dependent on temperature and battery type
B) Battery charge level approx. 80 %. The battery can be removed for immediate use.
C) Battery charge level approx. 95 % – 100 %.
A)
(80 %
A)
(80 %
BC1880
9 26 04 334 00 0
18 V
8.0 A
0 °C – 45 °C
B)
) / Battery charged
32 min / 51 min
68 min / 79 min
113 min / 126 min
B)
) / Battery charged
15 min / 30 min
5 – 15
1.46 lbs
0.66 kg
C)
C)
/ II