magnetic rotor assembly (see figure 8).
4 Remove the bowl gasket from its seat (see figure 9).
5 Dismantle the faucet assembly (see figure 10).
figure 10
6 Slide the drip tray out and empty it.
figure 7
figure 8
figure 9
7. 4. 2 CLEANING
IMPORTANT
Do not attempt to wash any machine components in a
dishwasher.
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source.
1 Prepare at least two gallons of a mild cleaning solution of
warm (45-60 °C 120-140 °F) potable water and dishwashing
detergent. Do not use abrasive detergent.
Important: if present, follow label directions, as a too strong
solution can cause parts damage, while a too mild solution will
not provide adequate cleaning.
IMPORTANT
In order to prevent any damages to the dispenser use
only a detergent suitable with plastic parts.
2 Using a brush, suitable for the purpose, thoroughly clean all
disassembled parts in the cleaning solution.
ATTENTION
When cleaning the machine, dump it, do not allow exces-
sive amounts of water around the electrically operated
components of the unit. Electrical shock or damage to
the machine may result.
3 In the same manner clean the evaporator cylinder(s) using
a soft bristle brush.
4 Rinse all cleaned parts with cool clean water.
7. 4. 3 SANITIZING
Sanitizing should be performed immediately prior to
starting the machine. Do not allow the unit to sit for
extended periods of time after sanitization.
Sanitization must be performed whenever the distributor is
put back into operation with a new product.
1 Wash hands with a suitable antibacterial soap.
2 Prepare at least two gallons of a warm (45-60 °C 120-
140 °F) sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with 2
litres of water) according to your local Health Codes and
manufacturer's specifications.
3 Place the parts in the sanitizing solution for five minutes.
4 Place the sanitized parts on a clean dry surface to air dry.
5 Wipe clean all exterior surfaces of the unit. Do not use an
abrasive cleaner.
7. 4. 4 ASSEMBLY
1 Slide the drip tray into place.
2 Lubricate faucet piston, outer spiral and outside magnetic
17