Technical Data; Power Requirements - PRETUL ESMA-4-1/2P2 Manual De Instrucciones

Ocultar thumbs Ver también para ESMA-4-1/2P2:
Tabla de contenido

Technical Data

Code
Description
Discs
Voltage
Frequency
Current
Power
Speed
Duty cycle
Conductors
Insulating
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
Tools with double insulation and reinforced insulation are
equipped with a polarized plug (one prong is wider than the other). This plug will
only fit in the right way into a polarized outlet. If the plug cannot be introduced
into the outlet, reverse the plug. If it still doesn't fit, call a qualified electrician to
install for you a polarized outlet. Do not alter the plug in any way. Both insulation
types eliminates the need of both a grounded third power cord with three prongs
or a grounded power connection.
WARNING
When using an extension cable, verify the gauge is enough for the power that your product needs. A lower
gauge cable will cause voltage drop in the line, resulting in power loss and overheating. The following table shows the right
size to use depending on cable's length and the ampere capability shown in the tool's nameplate. When in doubt use the
next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
11 000 RPM
18 AWG x 2C with insulating temperature of 221 °F
Class II
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
ESMA-4-1/2P2
24035
Angle grinder
4
/
"
1
2
127 V
60 Hz
5.3 A
0.93 Hp
Screwed thread size
20 minutes work per 10 minutes idle.
Maximum 1 and a half hour per day.
IP Grade:
Power cord grips used in this product: Type "Y".
Build quality: Reinforced Insulation
Thermal insulation on motor winding: Class F
Extension gauge
from 5.9' to 49.2'
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
5/8-11-UNC-1A
IP20
Authorized Service Center.
|
higher than 49.2'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3
Tabla de contenido
loading

Este manual también es adecuado para:

24035

Tabla de contenido