Gas connection:
EN
The pressure for the city gas connection must be 20 mbar. It is necessary to check its gas network pressure
as well as the nozzle installed on the appliance to avoid any damage and accidents.
If the gas pressure is lower than 18mbar or higher than 22.5 mbar, the device must not be connected.
MANUAL
CHIMNEY FOR TYPE A DEVICE DESIGN
Extractor hood with natural extraction (A). Flue gas provides a natural chimney draft.
Stopper at the outlet without natural extraction. Combustion gas is ensured by a fan (D) (forced extraction).
In this case it is necessary to ensure the connection with a gas supply (B) to the gas supply in case of failure.
CHECK OF THE SETTING OF THE APPLIANCE ON THE TYPE OF GAS
Our appliances are certified and regulated for natural gas (see the technical plate). Conversion or adaptation
to another type of gas must be carried out by authorized personnel. Nozzles for different types of gas are in
a bag supplied with the gas cooker and are marked in hundredths of mm (table of technical data pipes).
Nozzle replacement and pressure adjustment