Equalizing the cartridge materials
Observe the instructions of the material
manufacturer for the dispensed material!
Refer to figure {D} on page III:
1. Insert the cartridge as previously described
2. Set the adjustment wheel (2) to the lowest discharge
rate, position "1"
3. Actuate the trigger (1) until both components are
evenly pressed out of the cartridge
4. Release the trigger (1)
Fix the mixer onto the cartridge
Refer to figure {E} on page III:
1. Remove any external material from the cartridge
and the cartridge bed with a clean cloth
2. Screw the mixer (15) onto the cartridge, respectively
cap nut (18) onto the cartridge
Dispensing the material
Dispensers weighing more than 5 kg should
be carried with a shoulder strap that is
hooked into the eye (11) of the device.
Refer to figure {D} on page III:
1. Set the material discharge rate to position '1' with
adjustment wheel.
2. Actuate the trigger (1). The material is pressed out
of the cartridge into the mixer (15) and is discharged
from the tip of the mixer
3. Increase the discharge rate with adjustment wheel
(2) to suit the dispensing application
Instruction handbook ElectraFlow
Dual Ultra · Version 1.3 · 9.4.21
Remove the used cartridges
Refer to figure {G}, {H} on page IV:
1. Release the trigger (1)
2. Press the "Release" button (3) and hold it down
3. Holding the rack pull (8) manually, withdraw the
racks/ plungers from the cartridge
4. Remove the cartridge
MR only:
1. Supporting dispenser push cartridge sideways to
disengage from straps (13) and remove from
cartridge holder (7).
600/ Extended:
1. Supporting dispenser push cartridge back against
sprung locators (14) and pivot up to remove from
cartridge holder (7).
Dispose of the cartridge in accordance with
the manufacturer's instructions.
9 of 12