Technical Specifications
Inlet and Outlet Diameter
Maximum Suction Depth
Maximum Height (Maximum value of
total manometer height)
Maximum Flow
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
Power Requirements
WARNING
To prevent electric shock, the tool shall be grounded while
in use. • Connect the plug into a correctly grounded outlet as shown in
example A. Not all the outlets are properly grounded. If in doubt, verify with a
qualified electrician. • If the outlet where you will connect the tool has two
poles (2 orifices). UNDER ANY CIRCUMSTANCE, DO NOT REMOVE OR
ALTER THE PLUG'S GROUND CONNECTOR. Use a temporary adaptor as
shown in example B and always connect the ground conductor lug as shown.
CAUTION
When using an extension cable, verify the gauge is enough
for the power that the tool needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and the motor will overheat. The following table shows the right size to use depending on cable's
length and the ampere capability shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When using power tools outdoors use a
Use". These extension cables are specially manufactured for outdoors use and reduce the risk of electric shock.
WARNING
All the cabling, power connections and the ground connection of the system shall
comply with the OFFICIAL MEXICAN STANDARD NOM - 001 SEDE-2012, ELECTRICAL INSTALLATIONS
(UTILIZATION) or with the local codes or regulations. Use the services of a qualified electrician.
Code
Description
Voltage
Frequency
Current
Speed
Tank Capacity
Conductors
Duty Cycle
Insulation
Number of
Conductors
3 (one grounded)
HIDR-1/2x24P
20183
Hydro Pneumatic Pressure Boosting System
127 V
60 Hz
3.5 A
3450 RPM
1" x 1"
26.2 ft
65.6 ft
11 gal/min
6.3 gal
18 AWG
30 min work x 20 min rest. Maximum 6 hours
Class I
Power Cord Grips used in this product: Type "Y".
Tool Build Quality: Basic insulation
Thermal insulation on motor winding: Class F
Extension gauge
from 6' to 49'
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded extension cable labeled "Outdoors
HIDR-1/2x50P
20184
13.2 gal
18 AWG
Authorized Service Center.
A
B
CAUTION
|
higher than 49'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3