PRETUL BOAP-1/2P3 Manual
Ocultar thumbs Ver también para BOAP-1/2P3:

Enlaces rápidos

Manual
Peripheral
water pump
Applies for:
Code
Model
27019
BOAP-1/2P3
BOAP-1/2P3
CAUTION
Read the user's manual thoroughly
before operating this tool.
Agricultural Use
Tabla de contenido
loading

Resumen de contenidos para PRETUL BOAP-1/2P3

  • Página 1 Manual Peripheral water pump Agricultural Use Applies for: Code Model 27019 BOAP-1/2P3 BOAP-1/2P3 Read the user’s manual thoroughly CAUTION before operating this tool.
  • Página 2: Tabla De Contenido

    Parts Keep this manual for future references. Installation The illustrations in this manual are for reference Start Up only. They might be different from the real tool. Maintenance Troubleshooting Notes Authorized Service Centers Warranty Policy BOAP-1/2P3 ENGLISH...
  • Página 3: Technical Data

    Technical Data BOAP-1/2P3 Code 27019 Description Peripheral Water Pump Voltage 127 V Frequency 60 Hz Speed 3450 RPM Current Power 1/2 Hp Outlet and Inlet Diameter 1 NPT Maximum Suction Depth 26 ft Maximum value of manometric height 65.5 ft...
  • Página 4: General Power Tools Safety Warnings

    General Power Tools Safety Warnings WARNING! Read carefully all safety warnings and instructions listed below. Failure to comply with any of these warnings may result in electric shock, fire and / or severe damage. Save all warnings and instructions for future references.
  • Página 5: Safety Warnings For The Use Of Water Pumps

    Safety Warnings for The Use Of Water Pumps • Do not install the pump in areas WARNING Adequate Uses where there is danger of explosion or near combustible liquid and gases. • The pump is a stationary device designed to pump clean WARNING •...
  • Página 6: Installation

    Installation Mounting • The pump shall be installed in a dry place, away from the elements; with air flow to allow air flow for the adequate ventilation (A) Ambient temperature not exceeding 104º F • Use bolts to fix the pump onto a concrete base to prevent vibrations (B) The pump shall be installed in a horizontal position to assure it runs properly.
  • Página 7: Electrical Installation

    Installation Electrical Installation • Call a professional electrician to carry out the electric connection to the power supply, following the mandatory rules. • The fixed installation shall incorporate a device to assure the omnipolar disconnect from the power supply. • Make sure the electric requirements described in this Instruction Manual and the pump nameplate, match with the power supply value capacity.
  • Página 8: Maintenance

    Maintenance • The pump does not require maintenance only if following these simple precautions: • When there is risk of frost empty the pump completely. Remove the foot valve to drain the pipes. • If the pump will remain idle for long periods of time, it is recommended to empty it completely, rinse with clean water and store in a dry place.
  • Página 9: Troubleshooting

    Troubleshooting Problem Cause Solution The motor is not • There is no power • Check the connections and the power values. starting • The impeller is stuck • Release it with a screwdriver (see page 8) The motor turns but is •...
  • Página 10: Notes

    Notes ENGLISH...
  • Página 11: Authorized Service Centers

    Authorized Service Centers In the event of any problem contacting a Authorized Service Center, please see our webpage www.truper.com to get an updated list, or call our toll-free numbers 800 690-6990 or 800 0187-8737 to get information about the nearest Service Center. DE TODO PARA LA CONSTRUCCIÓN FIX FERRETERÍAS AGUASCALIENTES...
  • Página 12: Warranty Policy

    Model Brand 27019 BOAP-1/2P3 This product is guaranteed for 1 year. To make the warranty valid or purchase parts and components you must present the product in Corregidora 22, Col. Centro, Alc. Cuauhtémoc, CDMX C.P. 06060 or at the establishment where you purchased it, or at any Truper Service Center listed in the annex to the warranty ®...

Este manual también es adecuado para:

27019

Tabla de contenido