Alarm
Description
code
E111
TC1
E113
Gas over-temperature
E114
Failed ignition
E115
General error
6.2 Reset alarms
In case of an alarm the display turns red and an
acoustic signal (beep) is emitted.
The alarm code and possible cause is displayed.
The device shuts down.
Grate blocked
E104 - Empty and clean the burn
pot. Reset the error.
Hazard: In case of alarms "E108" or "E109",
before resetting the alarm, reactivate the
manual reset thermostat positioned on the
back of the device (by the Technical Service
Centre).
At this point it is possible to proceed with a
new ignition.
If the screen is closed by pressing
not reset and the icon
004778290 - 21/01/2021
ITALIANO
ENGLISH
Sensor connected to T03 malfunctioned or disconnected.
Call service.
Flue gas over-temperature. Clean the exchanger or chimney.
Fuel ignition timeout expired (empty the burn pot and restart the
device) or fuel tank empty (refuel the tank).
Call service.
Fig. 87
the alarm is
remains .
DEUTSCH
Possible causes
OFF
12
26,0 °C
To see the alarm description again press the icon
.
Before switching on again, check that:
• the device has cooled;
• the cause of the alarm has been resolved;
• the burn pot is clean and free from ash residue
or pellets:
• the burn pot is correctly positioned in its seat;
• the fire box and tank doors are firmly closed.
FRANÇAIS
ESPAÑOL
°C
AIR
Fig. 88
53