WARNING! A leak test must be performed annually and each time a cylinder is hooked up
or if a part of the gas system is replace
WARNING! Never use an open flame to check for gas leaks. Be certain no sparks or open
flames are in the area while you check for leaks. Sparks or open flames will result in a fire
or explosion,damage to property,serious bodily injury,or death.
Leak testing: this must be done before initial use,annually,and whenever any gas
components are replaced or service. Do not smoke while performing this test,and remove
all sources of ignition. See Leak Testing Diagram for areas to check. Turn all burner
controls to the off position. Turn gas supply valve on
Brush a half-and-half solution of liquid soap and water onto all joints and connections of
the regulator,hose,manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced
with one recommended by the Customer Care department and have the patio heater
inspected by a certified gas installer
If the leak cannot be stopped,immediately shut off the gas supply,disconnect it,and have
the patio heater inspected by a certified gas installer or dealer. Do not use the patio heater
until the leak has be corrected.
LEAK CHECK
29