Safety Information - KEUCO IXMO 59512 011140 Manual De Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
EN
These instructions are designed for the installation
engineer to assemble the product and for the user
to operate and maintain it.
After installation, please pass them on to the
user for safekeeping.
Symbols and their meaning
Caution! Warning against bodily injury or damage
to property.
Note, tip or reference
Incorrect installation
Correct installation/test of functionality
Observe installation details

Safety Information

– This device is not intended to be used by per-
sons (including children) with limited physical,
sensory or mental abilities, or with inadequate
experience and/or knowledge, unless they are
supervised by somebody responsible for their
safety and have received instructions from them
on how to use the device.
– Children must be supervised to ensure they do
not play with the device.
– Do not start the appliance if it or the power sup-
ply cable is damaged, but have it replaced by
the manufacturer, its customer service or by an
equally qualifi ed person.
Intended use
Sensor washbasin mixer for use in private and
public bathrooms and WCs.
Operation only possible in combination with the
AquaVip system from Viega.
Operation only with potable water.
Product is only suitable for installation indoors!
Attention! Only install in frost-free places.
Declaration of conformity! This product complies
with the requirements of the valid EU Guidelines.
The declaration of conformity for this product can
be requested from the following address:
KEUCO GmbH & Co. KG, Oesestraße 36,
D-58675 Hemer.
6
Important information, please make sure to read!
Technical specifi cations
– Ambient conditions:
Temperature
– Flow at 3 bar pressure:
– Pressure:
min. 0.5 bar/recommended 1-5 bar
– Operating pressure
– Test pressure:
Factory settings
– Detection zone:
– Run-on time:
– Water stop:
Mounting dimensions, refer to page 2
Installation, see from picture 1 on page 30
Flush potable water pipes thoroughly before and
after installation (observe EN 806 and 1717, as
well as DIN 1988).
Test connections for leaks with water pressure.
Oprating, see from picture 6 on page 31
When the sensor washbasin mixer is ready for use:
- Hold hand in front of sensor window
- Water comes out at the preset temperature
Activate cleaning mode
– Cover the lower half of the sensor window with your
fi nger for 5 s. The water fl ow starts, and stops after 5
s. Now take your fi nger away from the sensor window.
The water fl ow is now interrupted for 180 s.
Servicing
Cleaning aerator, replacing if necessary, refer to fi gure 7
on page 31
Assemble in reverse order.
For spare parts with order numbers, refer to page 35
For information about warranty and maintenance,
see the enclosed Care Instructions and Warran-
ty Card.
Disposal information! Equipment with this
labelling must not be disposed of in household
refuse, but must be disposed of at a collection
centre intended for this purpose.
Dispose of batteries according to laws and
regulations that are applicable locally.
5°– 40° C
max. 5 l/min
max. 8 bar
16 bar
~16 cm (factory setting)
1 s
30 s
Tabla de contenido
loading

Este manual también es adecuado para:

Ixmo 59512 371140

Tabla de contenido