Maintenance; Power Cord - Mobiclinic TIBET Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ES

7. MAINTENANCE

STORAGE: Keep your equipment in a closed space, away f rom dust and
humidity.
POWER CORD: Ensure the cable and the plug are in good condition.
SCREWS AND CABLES: Check and tighten the screws often, as due to
the vibration screws and nuts tend to loosen. Check regularly that the
cables are in good condition.
LUBRICATION: It is very important to properly lubricate the running belt
with silicone or teflon oil. This lubrication must be applied regularly,
even before the f irst use. There is an orif ice to add the oil in the engine
cover. It is recommeded to add the oil with the machine programmed at
the top speed.
< 3 hours / week
2 months
4 - 7 hours / week
1 month
> 8 hours / week
15 days
BELT ALIGNMENT: Due to use, the belt might move off center. If the belt has
been displaced to the left, start the treadmill and turn the speed up to 3 MPH.
Use the 5 mm wrench to turn the fixed left bolt clockwise or turn the right
bolt counter-clockwise. Do not tighten the belt too tautly to be able to walk.
Repeat the procedure until the belt is properly aligned. If the belt slips, use
a 6 mm wrench and tighten the screws on both sides, turning 1/4 clockwise.
Reapeat this procedure until the belt is firmly tightened.
CLEANING: Do not use abrasive products. A wet cloth is sufficient.
MADE IN P.R.C.
16
Tabla de contenido
loading

Este manual también es adecuado para:

Fitness tibet

Tabla de contenido