What If There Are Problems - Beurer BF 880 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31

5. WHAT IF THERE ARE PROBLEMS?

5.1 Restarting scale
If it is necessary to restart the scale (e.g. scale software freezes). Remove the batteries briefly.
5.2 Resetting the scale to factory settings
1. Press and hold the SET button
2. Press the SET button
3. Press the
/
button
5.3 Updating scale software
The app will inform you when a new software update is available.
1. Briefly press on the scale to switch it on.
2. Press and hold the
loads it. This may take a few minutes. If the update is successful, "PASS" will be displayed. If the scale is
already up to date with the latest software version "utd" appears.
5.4 Messages and errors
Display
Discrepancy in
weight
PAir
"USE APP" or
flashing
UnSt
U: --
BF--
oLd
Lo
Err1
Err2
Er3...
Err4
utd
no
for 4 seconds. "unit" flashes on the display.
3
three times until "SET" flashes on the display.
3
and confirm "rSt" using the SET
2
4
button
for 15 seconds. The scale automatically checks for an update and down-
2
Cause/remedy
Incorrect zero point (e.g. in the event of a change of location or temperature fluctua-
tion): briefly press on the scale until the current weight is displayed, then remove your
foot so that "0.0" flashes.
Scale is placed on carpet or uneven ground: the surface must be hard and level.
Bluetooth
needs to be paired: start/allow pairing/bonding on your smartphone (note
®
any messages in the status bar/notification bar), and confirm the 6-digit pairing code
using the SET button
The scale can be connected to the app via Bluetooth
Bluetooth
settings on your smartphone, only via the app.
®
This weight measurement was unstable: stand still during the measurement.
The scale was unable to assign the measurement to a scale user: if the automatic
scale user detection function is not working, briefly press the scale with your foot,
press the
button
2
onds. Weigh yourself again.
The body fat percentage is outside the measurable range (less than 5% or greater
than 70%): check the user data or change the activity level.
Diagnostic measurement cannot be taken (e.g. measurement attempted while wear-
ing shoes): Repeat the measurement barefoot. Otherwise, only weight values will be
displayed and transferred.
The maximum weight capacity of 180 kg has been exceeded: loads must not exceed
180 kg.
Batteries are flat. Replace the batteries.
Incorrect password for your selected WIFI network/SSID/router.
Your router does not have Internet access. The server cannot be reached.
Software update failed: please try again.
Booting problems: Remove the batteries briefly.
The software is up to date.
There is no WIFI connection to the server for the software update.
button.
3
on the device and on the smartphone.
3
repeatedly until your scale user is displayed, and wait 3 sec-
18
: do not connect it via the
®
Tabla de contenido
loading

Tabla de contenido