1)
To install glass panels: NOTE: Side Glass Panels (Quantity 3)
are larger than Door Glass Panel (Quantity 1).
Raise latch up on side of fixture with hinged door. Pull door
open. Carefully insert one glass panel into cage of fixture.
Tilt glass and fit top edge of glass into channel along top of
one side of cage. Carefully lower glass down and fit bottom
edge of glass panel into bottom channel on side of cage.
Repeat these steps for remaining glass panels.
2)
Pass fixture wire through end of threaded pipe with hexnut.
Screw end of threaded pipe with hexnut into coupling on top
of fixture.
3)
Pass fixture wire through tube. Slip tube down over threaded
pipe on top of fixture.
4)
Lower ring down over top of fixture. Pass fixture wire through
hole in center of ring. Pass hole in center of ring over end of
threaded pipe protruding from tube on top of fixture.
5)
Pass holes at ends of ring over ends of threaded studs on
sides of roof of fixture.
6)
Thread one threaded cap onto each threaded stud. Tighten
threaded caps to secure ring to roof.
7)
Pass fixture wire through hole in check ring. Slip check ring
down over end of threaded pipe protruding from top of ring.
8)
Pass fixture wire though hole in bottom of loop. Thread loop
onto end of threaded pipe.
9)
TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your
home. Place the main power switch in the "OFF"
position.
b) Unscrew the fuse(s), or switch "OFF" the circuit breaker
switch(s), that control the power to the fixture or room
that you are working on.
c) Place the wall switch in the "OFF" position. If the fixture
to be replaced has a switch or pull chain, place those in
the "OFF" position.
10) Take threaded pipe from parts bag and screw in screw collar
loop a minimum of 6 mm (1/4"). Lock into place with hexnut.
11) Run another hexnut down threaded pipe almost touching
first hexnut. Now screw threaded pipe into mounting strap.
Mounting strap must be positioned with extruded thread
faced into outlet box. Threaded pipe must protrude out the
back of mounting strap. Screw third hexnut onto end of
threaded pipe protruding from back of mounting strap.
12) Connect mounting strap to outlet box.
13) Unscrew the threaded ring from screw collar loop. Take
canopy and pass over screw collar loop. Approximately one
half of the screw collar loop exterior threads should be
exposed. Adjust screw collar loop by turning assembly up or
down in mounting strap. Remove canopy.
14) After desired position is found, tighten both top and bottom
hexnuts up against the bottom and top of the mounting
strap.
15) Slip canopy over screw collar loop and thread on threaded
ring. Attach chain (with fixture connected) to bottom of
screw collar loop. Unscrew threaded ring, let canopy and
threaded ring slip down.
16) Weave electrical wire and ground wire through chain links no
more than 3 inches apart. Pass wire through threaded ring,
canopy, screw collar loop, threaded pipe and into outlet box.
17) Grounding instructions: (See Illus. A or B).
A)
On fixtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector
(not provided.) after following the above steps. Never
connect ground wire to black or white power supply wires.
A
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
GREEN GROUND
SCREW
Date Issued: 1/17/14
B
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
CUPPED
GREEN GROUND
SCREW
WASHER
HEXNUT
TUERCA HEXAGONAL
CANOPY
ESCUDETE
THREADED RING
ANILLO ROSCADO
THREADED PIPE
TUBO ROSCADO
Glass Panel A
Panel de vidrio A
Panneau de la
18) Make wire connections (connectors not provided). Reference
chart below for correct connections and wire accordingly.
19) Raise canopy to ceiling.
20) Secure canopy in place by tightening threaded ring onto
screw collar loop.
FIXTURE
21) To install bulbs, raise latch up on side of fixture with hinged
GROUND
door. Pull door open.
22) Insert bulbs into sockets.
23) Close door. Lower latch inserting bottom of latch into hole in
channel on fixture.
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
We're here to help
ABRAZADERA DE MONTAJE
THREADED PIPE
TUBO ROSCADO
SCREW COLLAR LOOP
OJAL DE COLLAR ROSCADO
LOOP
ANILLO
ANILLO DE SEGURIDAD
RING
ANILLO
TUBE
TUBO
Door Panel
puerta
Connect Black or
Red Supply Wire to:
Black
*Parallel cord (round & smooth)
Clear, Brown, Gold or Black
without tracer
Insulated wire (other than green)
with copper conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
866-558-5706
Hrs: M-F 9am to 5pm EST
MOUNTING STRAP
CHECK RING
THREADED CAP
TAPA ROSCADO
THREADED STUD
ESPÁRRAGO
ROSCADO
GLASS PANEL
PANEL DE VIDRIO
Glass Panel B
Side Panel
Panel de vidrio B
Panel lateral
Connect
White Supply Wire to:
White
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with silver conductor
Neutral Wire
IS-43259-US