MAINTENANCE
After each use, wipe the cups and other components
with a damp cloth to remove dust and debris.
Occasionally lubricate the leveler threads with white
lithium grease.
Store the VMP750 pumps in a dry place at room
temperature. For long-term storage, keep the
batteries at about 30% charge.
Keep the protective covers on the vacuum cups
when not in use.
Do not use acetone or other solvents to clean the
vacuum cups.
Regularly clean the felt filters with compressed air.
Regularly inspect the vacuum cups to ensure the
sealing rings are free of cuts, tears, deformities, or
abrasions. Replace cups as needed.
Occasionally inspect the plungers to ensure they are
clean and the rubber piston seals are moderately
lubricated with petroleum jelly.
Occasionally test vacuum cup functionality. (See
page 15)
Contact Omni Cubed Customer Service for
troubleshooting and replacement parts.