2.
This does not apply if the plug was disconnected from the power socket. In
that case, the appliance will lose its memory function and you will have to
adjust all settings again.
SAFETY DEVICE
1.
The following situations may trigger the internal safety device, causing the
appliance to switch off:
If the temperature rises above 43°C or the room temperature drops below
15°C in Cooling mode.
If the room temperature drops below 15°C in Dehumidifier mode.
If the air conditioner operates in "Cool" or "Dehumidify" mode and the
window in the room is opened for an extended period, causing the relative
humidity to rise above 80%, condensation may drip out of the appliance.
2.
Caution: If operation is interrupted, the internal safety device of the compressor
will switch on. In that case, the compressor cannot be switched on for 3 minutes,
allowing for regulation of the cooling circuit. There is no defect. Wait for
3 minutes before switching the appliance back on.
RESIDUAL WATER AND WATER TANK
1.
The appliance is self-evaporating. This means that the condensation water
produced by the cooling evaporates and is discharged to the outside via the
hose. However, in very humid weather, some water may collect in the small
water tank inside the device. In this case E4 appears in the display. Then
do the following:
2.
Have a wiping cloth and a shallow receptacle ready.
3.
Draining the water is easier if you elevate the appliance slightly, e.g. by
placing it on a stool. Make sure to provide for sufficient stability to keep the
appliance from falling off.
4.
Disconnect the plug of the appliance from the power socket.
5.
Remove the cover cap from the water drain. Make sure not to lose the cap.
6.
Carefully allow the condensation to drain, tilting the appliance slightly as
needed.
7.
Refit the cover cap securely on the water drain as water may otherwise
escape from the appliance and cause damage.
8.
You can now put the appliance back into operation.
Stand 9.8.2022
DE
EN
FR
NL
IT
ES
PL
45 von 152