The product can be damaged if the gas cylinder is moved!
Entrained liquid phase can cause the pressure to increase in the LPG system and damage
the product or the LPG system.
Do not move the gas cylinder while the system is in operation.
OPERATION
Always turn the changeover device as far as it will go to the operating or reserve side!
No intermediate position.
Type of withdrawal
Operation
GREEN on the changeover
device points to the
cylinder(s) on the operating
side.
The visual indicator is at
GREEN "operation".
Reserve - operating side
is empty
GREEN on the changeover
device points to the
cylinder(s) on the empty
operating side. The visual
indicator is at RED
"reserve".
Type of withdrawal
Cylinder replacement
during operation
Set the changeover device
so that GREEN is pointing
to the cylinder(s) on the
reserve side. The visual
indicator changes from
RED "reserve" to GREEN
"operation". Perform
LEAK TESTING.
Cylinder replacement during operation
1. Set the changeover device so that GREEN is pointing to the cylinder(s) on the spare side.
2. Close the cylinder valve of the empty gas cylinder
3. Loosen the connections to the gas cylinder
4. Replace the empty cylinder with a full one and connect the full one.
The gas non-return valve prevents the gas flow from escaping through the free
connection
during cylinder replacement.
5. Open the cylinder valve and check for leaks. 6. The full cylinder is available as a spare.
Artikel-Nr. 71 923 50
Operation
Reserve
Caramatic ProTwo
Caramatic ProTwo
Reserve
Operation