7
Tips for fault diagnostics:
Symptom
Mögliche Ursache
Pump does not
The container is empty.
produce any
The grease supply has been
grease.
interrupted.
There is a lack of air pressure.
Faulty pump
The air motor of
The air filter of the pump is dirty
the pump is
or clogged
working too
slowly
8
Specifications:
Pressurised air pump pneuMATO
Size of device
Pressure transfer
Max. delivery pressure at 8 bar compressed air
connection.
Flow rate per double stroke
Grease NLGI class 000
Grease NLGI class 2
Air pressure min./max.
Volume level:
Thread
Air connection
Grease outlet
Suction tube diameter
Suction tube length
Weight
Lubricants:
Grease up to the consistency of 2 (NLGI / Class 2 according to DIN 51818) can be used. Pastes
without lubricative properties (with abrasive sandpaper parts) must not be handled with this device.
9
Disposal
After termination of use the device is to be disposed of in an environmentally
friendly manner in accordance with applicable statutory provisions.
Grease-tainted parts do not belong in the dustbin!
The applicable regulations for the registration, installation and operation of equipment for
handling of substances hazardous to water are to be strictly observed by the operator (such
as, e.g., Federal Water Act, German Ordinance on Exposure to Substances Hazardous to
Waters and Technical Rules and Regulations for Flammable Liquids).
12
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120
GmbH & Co. KG
MATO
Behebung
Check the level of container.
Vent the pump.
Check supply line.
Replace pump.
Clean air filter
pneuMATO-fill
10-25 kg
50 kg
24 bar
20 ccm
3500 ccm / min
1750 ccm / min
3 – 8 bar
ca. 85
Rp ¼"
40 mm
525 mm
790 mm
5.5 kg
5.6 kg
Operating manual
pneuMATO-fill
Air Filter
200 kg
1000 l
1:3
dB(A)
R ½"
940 mm
1490 mm
5.8 kg
5.9 kg