Safety
Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Installation
Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Technical
Data
This
mixer
series-produced
with
EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
4
English
®
(flow
®
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly
see
page
31
Symbol
description
Do not use silicone containing acetic acid!
Dimensions
(see page 34)
Flow
diagram
(see page 34)
with EcoSmart
without EcoSmart
Spare
parts
(see page 36)
XXX = Colors
000 = chrome plated
820 = brushed nickel
Operation
(see page 35)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Cleaning
see enclosed brochure.
Test
certificate
(see page 36)
®
®