Fanaway Montclair Installation Instructions
WARNING: FOR YOUR SAFETY,
electrician.
NOTE: AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED
WIRING.
From mains supply to mounting bracket terminal block: (Fig. 8)
Connect the live supply wire to the "L" terminal of the terminal block on the mounting bracket.
1.
Connect the neutral supply wire to "N" terminal of the terminal block on the mounting bracket.
2.
Connect earth wire to the "
3.
From mounting bracket to receiver and fan motor : (Fig. 8)
Connect the supply wiring quick connector from the mounting bracket to the input quick connector of the fan
receiver . (Fig. 8)
Connect the output wires quick connector of fan receiver to the input wires quick connector of the fan
assembly. (Fig. 8)
8 | P a g e
ELECTRICAL WIRING DIAGRAM THE FAN
Electrical installation should be performed by a qualified licensed
" earth terminal of the terminal block on the mounting bracket.