American Standard TOWNSEND 7353.101 Instrucciones De Instalación página 2

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2
INSTALL DRAIN FROM BELOW FIXTURE
DRAIN
OUTLET
1
• Install DRAIN (1) by dropping it from the top of the sink.
• From under side of SINK install GASKET (2) and
MOUNTING NUT (3).
Note: Plumber's putty or caulk is recommended.
4
FLANGE GASKET AND POP-UP KNOB
FOAM
GASKET
NOT VISIBLE
• Check DRAIN FLANGE in SINK to ensure that
FOAM GASKET (3) is fully compressed and not visible.
6
MAKE WATER SUPPLY AND WASTE CONNECTIONS
• Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right
supplyto COLD (2) wall supply.
• Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer
must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop
as illustrated to avoid kinking.
• Connect 1-1/4" O.D. tailpiece on POP-UP DRAIN to
waste outlet.
REAR OF SINK
2
3
DRAIN
FLANGE
3
• Thread TAIL PIECE NUT (1) clockwise onto
DRAIN BODY (2).
5
CHECK OPERATION OF POP-UP
• Operate DRAIN STOPPER (1) to verify that it opens
and closes.
APPROX. 20"
1
- 2 -
2
1
1
2
BLUE
RED
BAND
BAND
3/8" COMPRESSION
HOT
COLD
M965722 Rev. 1.2 (10/20)