WPE DIESEL GENERATORS
you should disconnect the cables at the generator
first.
5. Charge the battery in a well ventilated place. Before
charging, remove the cap from each cell of the
battery. Discontinue charging if the electrolyte
temperature exceeds 45°C.
WARNING
Do not attempt to start an automobile engine while
the generator is still connected to the battery.
NEVER try to use both DC 12 volt and AC at the same
time.

Stopping the generator

1. Turn off the AC circuit breaker.
2. Leave the engine speed lever in the "RUN" position,
operate the engine without load for approx 3 minutes,
DO NOT stop the engine suddenly because this may
cause the temperature to rise abnormal and cause
the nozzle to damage and seize the engine.
3. Push down the stop lever or Turn the ignition key
anticlockwise to "OFF" position .
WARNING
If the engine keeps on running even after the speed
lever is pressed at the "Stop" position, turn the
ignition key to 'OFF' position. NEVER try to stop the
engine with the decompression lever (Open Frame
Type Only)
Remote Control (If Applicable)
Generator can be started or stopped remotely using a
wireless transmitter
1. Ensure lever is in 'RUN' position
2. Leave ignition key in 'OFF' position (No Clockwise
Turn).
3. To start engine, press and hold button 'A' on
transmitter for approx. 3-5 seconds.
4. If generator does not start repeat 1-2 steps and retry.
5. To stop engine press 'B' button on transmitter.
WARNING
In electric key start mode: After the generator is
stopped or not in use you MUST turn the ignition key
to the 'OFF' position otherwise battery will flatten
over time.
If Generator doesn't start after 3 attempts,
steps 1-3 need to be REPEATED as well as general
maintenance of oil level and fuel level need to be
checked.
Never allow anybody other than the owner or
user to remotely start or stop the generator using
the wireless transmitter. Constantly starting and
stopping the generator will damage electric/
electronic components or equipment and also will
cause increased engine wear.
If the generator doesn't not start at all after many
attempts there may be malfunction or fault and you
will need to contact your local service centre on
44(0)1942 715 407.
NEVER run the generator on MAX watts for longer
than 10mins, by doing so you will cause the engine to
start to stall and overheat risking fire, immediately
stop the generator and allow to cool for minimum
30mins.
MAINTENANCE
Periodic check and maintenance are very important for
keeping the engine in good condition. Please read the
detailed description of operating manual for each part.
Shut off the engine before performing any maintenance.
If the engine must run, make sure the area is well
ventilated. The exhaust contains poisonous carbon
monoxide gas.
After the engine has been used, clean it immediately with
a cloth to prevent corrosion and remove sediment.
Recommended Engine Oil Type
5W-30
5W-30 Full Synthetic
°F
-20
0
20
°C
-28.9
-17.8
-6.7
Ambient temperature
DAILY
— Check oil level
— Check and replenish fuel
— Check for oil leakage
— Check and tighten and engine parts if loose
7
MAINTENANCE
WARNING
WARNING
10W-30
10W-40
40
60
80
100
4.4
15.6
26.7
37.8
48.9
EN
120