Maintenance
Cleaning the outside of the air purifier
1. Switch off the device and pull the plug.
2. Use a soft and humid piece of cloth to clean the device from dust and dirt.
3. Make sure that no water gets into the device.
Replacing of filters
The Clean Air Optima Air Purifier CA-502Pro Mini is equipped with a filter lifespan surveillance
mechanism that signals that the filters have to be replaced after 400 working hours. To show
that the composite filters (HEPA + Activated Carbon Filter) need to be replaced, the indicator
light will light up. Reset the timer for the composite filter by pressing and holding the button
Timer (for about 3 seconds). If the indicator light goes out, the timer has been successfully
reset.
Depending on the use, the composite filters (HEPA + Activated Carbon Filter) has a lifespan
of approx. 2-3 months.
Filter cleaning
The best effect is reached by cleaning the filters once a month. If indoor air is extremely polluted,
more cleaning can be required.
Clean the Pre-filter and the HEPA filter with a brush or your vacuum cleaner. That way bigger
dust particles like lint, hair and dander of pets can be removed from the filter.
Warning! Do never wet or rinse the composite filters (HEPA + Activated Carbon Filter)
with water.
Signs for used up filters
Increased sound, reduced air flow, congested filters, rising presence of smells. The filter needs
to be replaced by a new one when the HEPA filter changes its color from white to grey or black.
If the HEPA filter remains white, there is NO need to replace the filter.
How to order filters:
Contact Clean Air Optima Customer Service tel. + 31 (0) 742670145 or visit our webshop:
https://www.cleanairoptima.com/accessoires/mg/44/