us_main.book.book Page 15 Friday, August 19, 2022 2:09 PM
Green Wire (Ground)
e
UL-listed Conduit Connector
f
Black Wires
g
Junction Box
h
White Wire (No Connection)
i
Installing the Cooktop Unit
1
Visually inspect the cooktop for damage.
Make sure all cooktop screws are tight (see
below for locations).
3 Screws (Same Both Side)
a
4 Screws (Same Both Side)
b
2
Check and prepare the installation location.
• See Dimensions and Clearances.
3
Carefully lower the cooktop into the
countertop cutout, making sure not to trap
any wires.
NOTE
• Do not use caulking compound. The cooktop
must be removable, should service be required.
4
Attach the retainer brackets
of the cooktop; then snug the bolts against
the bottom of the countertop as shown.
NOTE
• The retainer brackets MUST be installed to meet
local codes or, in their absence, with the National
Electrical Code ANSI/NFPA No. 70, latest edition.

Final Check

Perform a final operational check of the cooktop,
making sure the cooktop powers on properly and
that each cooking zone operates correctly. Refer to
the Operating Instructions in this guide for details.