GB
The following manual apply for Kongskilde HP50-2 and
HP50-F power units
Description:
It is important that these instructions are read
and understood before installing or operating this
equipment. Electrical installation should be carried
out by a suitably qualified engineer.
How it works:
The HP50-2 and HP50-F Power Unit is used to supply
the high voltage to the static elimination equipment
which operates with 5,5-6kV.
The Power Unit converts the main voltage into a high
voltage of approximately 5.500-6.000V. The design of
the transformer limits the current of this output to 5mA
to make it conform to international safety standards. It
uses either 50Hz or 60Hz - please check the label on
your power unit before use.
The HP50-2 and HP50-F power unit uses uniquely
designed swivel connectors and can power up to four
static eliminator bars.
Checking on delivered
equipment:
The equipment leaves our factory in suitable protective
packaging. Please check that it is undamaged when it
arrives. If there is visible damage contact the factory or
one of our distributors immediately, before carrying out
any installation.
Loose parts enclosed is an IEC cable and nylon "P"
clip.
2
Connecting the power unit:
Electrical supply:
230V 50Hz - please check labels before use. The
power unit is rated 20VA at 230V.
Rating: 0,5A. The power unit is connected to the single
phase mains supply. The mains supply must provide an
earth.
Connect an earth wire to earth stud on the power unit
for additional security.
Connecting the static bars:
Remove plastic cap from threaded bush on power unit.
Push in cable connector. Hand tighten to ensure a good
connection.
Safety:
Current limited to 5mA. If there is a fault with one of
the static eliminators, it will try to draw more than 5mA,
causing the power unit to shut down. If the fault is
rectified, or the faulty static eliminator disconnected, the
power unit will spring back into action. It is important to
remember this when diagnosing a fault.
Load:
The load capacity is restricted by the 5mA current
limitation. Kongskilde products are more powerful than
most competitive products and so draw more current
from the power unit. The screened cable on all static
eliminators also has a heavy load.
The maximum load is:
HP50-2: 12 m of combined bar and cable length.
HP50-F: 25m of combined bar and cable length.
Conditions:
Maximum temperature 50° C. Keep dry and oil-free