Function
General
The BE1480 Visit smoke alarm is a radio transmitter within the Visit system for indoor
use, which detects smoke and heat. The Visit smoke alarm does this even more
reliably than smoke alarms which only have one of these functions. When smoke and
abnormal heat is detected, the Smoke Alarm will transmit a fire alarm signal to all Visit
receivers which are within its range while chirping like a normal smoke alarm.
Radio Key
On delivery all Visit units are tuned to the same Radio Key. If you have a neighbour
with a similar system, you can change to different Radio Keys so that you do not affect
each other's systems. If you use the Radio Key Switch (6) to change the Radio Key on
this transmitter, you must also change all other units in your Visit system to the same
Radio Key. Refer to the user manual for the relevant unit.
Broadcasting
On delivery the Visit smoke alarm is set to only transmit signals to systems which are
set to the same radio key as the Smoke Alarm.
By changing the broadcast switch (7) to ON, the operation of the smoke alarm can
be changed so that it transmits the smoke alarm signal to all Visit receivers within its
range regardless of the radio key that is set.
Note that the battery warning signals and activation via the test button (1) are only
transmitted to receivers with the same radio key as the smoke alarm regardless of the
broadcast key setting.
Reduced sensitivity function
Where you know in advance that you are going to generate smoke, e.g. when you are
frying food or lighting a fire, you can set the Visit smoke alarm to a less sensitive mode
by giving a short press on the test button (1). To indicate that the smoke alarm is in
this mode, the LED (1) will blink rapidly twice with a yellow light and then once with a
red light and beep twice in quick succession.
When the smoke alarm is in reduced sensitivity mode the LED (1) will blink twice with
a red light at 8 second intervals.
With another short press on the test button (1), the smoke alarm will return to normal
sensitivity. To indicate that the smoke alarm has returned to normal sensitivity, the
LED (1) will blink rapidly three times with a yellow light and then once with a red light
and beep three times in quick succession.
After approximately 20 minutes the Visit smoke alarm automatically returns to normal
sensitivity if it is not reset manually.