11. Secure indicator faceplate to housing using four
previously removed screws and Phillips screwdriver.
(See Figures 19-20)
Figure 19
ENTER TECHNICAL PARAMETER MODE
NOTE: Must use 10% of capacity to calibrate.
1.
Press ZERO and TARE keys at the same time. The
display will show "F1 UNIT".
2. Press TARE key until display shows "PROG" and press
ZERO key to show "PN" on the display.
3. Press in order M+, U and TARE keys to enter technical
parameter setting mode.
4. Press TARE key to select parameter, press ZERO key
to enter value and U key to exit.
5. It may be necessary to use TARE key to set a value
or use M+ and PT keys to move the active digit.
PAGE 4 OF 12
INSTRUCTIONS CONTINUED
Figure 20
CALIBRATION
1-800-295-5510
12. Complete calibration. (See Calibration below)
CALIBRATION
1.
Enter Technical Parameter Setting mode (see
Enter Technical Parameter Mode) until display shows
"P1 rEF".
2. Press the TARE key until display shows "P2 CAL".
Press ZERO key to enter and press TARE key until
display shows "CAL".
3. Press ZERO key twice and display will show "UNLD".
Remove all weight from the forks. After STABLE
indicator is visible, press the ZERO key.
4. The display shows the calibration weight value. Use
the M+, PT and TARE keys to set the weight value.
NOTE: Use M+/PT keys to move active digit, use
TARE key to change value. You can also press
G/N to make value zero.
5. After weight is keyed, press ZERO key to enter.
Display will show "LOAD".
6. Add calibration weight onto forks. After STABLE
indicator is visible press ZERO key to enter.
Display returns to normal once calibration is successful.
If an error message is shown, try the calibration steps
again; a disturbance may have prevented a successful
calibration. If the problem persists, please contact
Uline Customer Service at 1-800-295-5510.