Clean the filter base
1.Open the maintenance grille.
2.Unscrew the two locking levers towards each other.
3.Clean the entire filter base.
4.Insert the filter base again.
5.Screw the two locking levers back on.
6.Close the maintenance hatch until it clicks into place.
Locking lever
NOTE
• Lint accumulated on the filter prevents proper air
circulation, which leads to longer drying times and higher
energy consumption;
• Before cleaning, unplug the power cord!
• The dryer should never be operated without its filter!
• Clean the filter after each use to prevent residue from
accumulating in the machine.
Cleaning the thermal condenser
When necessary (approximately every two months), remove lint from the thermal condenser
with a sponge or soft brush.
Please wear gloves during this procedure.
14
Filter base
Maintenance
grille
EN
NOTE
It is easier to remove lint by moistening it beforehand,
for example with a laundry spray bottle.
Maintenance of the air condenser
-
Let the dryer cool down.
-
Residual water may run out. Place an absorbent cloth under the maintenance hatch.
1. Unscrew the maintenance hatch.
2. Open the maintenance hatch completely.
3. Screw both locking levers towards each other.
4. Pull the condenser towards you to remove it.
5. Clean the condenser well and let it drain completely.
15