Safety Instructions and Warnings
EN
!
!
Do not open the device!
Before any installation, or maintenance, ensure that the main switch is
switched off and prevented from being switched on again.
The device can be installed and put into service by qualified personnel
only.
Never work on the device if power is applied.
Risk of electric arcs and electrical shock, which can cause death,
severe personal injury or substantial property damage.
The unit must be connected to the mains supply in compliance with
national regulations (e.g. VDE0100 and EN50178).
All input and output PCB connections must be properly rated and
must be connected with the correct polarity. Fig.1
The host PCB tracks must NOT be routed directly under the Power
supply
The Power Supply input connections must be sufficiently fused.
Do not introduce any objects into the device.
Keep away from fire and water.
The internal fuse is not accessible. If this internal fuse has blown, the
power supply has an internal defect and, for safety reasons, must be
shipped to the local distributor.
The Power Supply must be scrapped if the pins are damaged.
The device is designed for use in a clean, dry environment.
The device shall be mounted in an enclosure in the end application. The
power supply is not accessible in operation.
Please observe that the temperature at the Tc point is not exceeded.
Recycling
The device contains elements that are suitable for recycling, and
components that need special disposal. You are therefore requested to
make sure that the device will be recycled at the end of its service life.
Order Code
SPECIFICATIONS
TMW 36-
112P
124P
Nominal Input Voltage
100 - 240 VAC
Nominal Input Current
0.7-0.4A
Operational Input Voltage Range
85 - 264 VAC
Input Voltage Frequency Range
47 - 63 Hz
Inrush Current (115/230VAC)
25/50A
Circuit Breaker Rating / Characteristic
6 - 16A/ Characteristic B or C
Max. Output Power
36 W
Output Voltage
12 VDC
24 VDC
Max. Output Current
3.0 A
1.5 A
Power Factor λ
0.5
0.5
Typical Efficiency (230 VAC)
87%
88%
Operating Temperature Range
- 20 °C to +80 °C
Max. Case Temperature Tc (Fig.1)
93 °C
93 °C
Output Power Derating - Input Voltage
2%/V below 100VAC
Above 50°C 2%/K;Vin≥187VAC
Output Power Derating - Temperature
Above 40°C 2%/K;Vin<187 VAC
Protection Class
Class II
Means of Protection (Input/Output)
2 x MOPP
Degree of Protection
IP68
Leakage Current (max)
100 µA
Touch Current (max)
100 µA
Network Configuration
TN-S, TN-C, TT, IT
Humidity
0 - 100%
Storage Temperature
- 40 °C to +90 °C
5000 m/50-106kPa
Maximum Altitude
(3000m - IEC61558-2-8)
Rev. Oct 19,2020 Doc No.>>TMW-P Installation Instruction>>
Sicherheitsinstruktionen und Warnungen
DE
!
!
Das Gerät nicht öffnen!
Ÿ
Ÿ
Vor Installations- oder Wartungsarbeiten muss sichergestellt sein,
dass der Hauptschalter der Applikation ausgeschaltet ist und ein
Einschalten verhindert wird.
Ÿ
Das Gerät darf nur von qualifiziertem Personal installiert und in
Betrieb genommen werden.
Nie am Gerät arbeiten, wenn Spannung angelegt ist.
Ÿ
Es besteht das Risiko eines elektrischen Schlages und Entstehung
Ÿ
von Lichtbögen, welche lebensgefährliche Körperverletzungen oder
Sachschäden verursachen können.
Der Anschluss des Geräts an das Versorgungsnetz muss den
Ÿ
nationalen Vorschriften entsprechen (z.B. VDE0100 und EN50178).
Ÿ
Alle Ein- und Ausgangsanschlüsse zur Leiterplatte müssen
fachgerecht bemessen sein und mit korrekter Polung erfolgen. Fig.1
Die Leiterbahnen der Zielplatine dürfen NICHT direkt unter dem
Ÿ
Netzteil verlaufen.
Die Eingangsanschlüsse des Netzteils sind ausreichend abzusichern.
Ÿ
Es dürfen keine Gegenstände in das Gerät eingeführt werden
Ÿ
Von Feuer und Wasser fernhalten.
Ÿ
Die interne Sicherung ist nicht zugänglich. Falls diese auslöst hat die
Ÿ
S t r o m v e r s o r g u n g e i n e n i n t e r n e n D e f e k t u n d m u s s a u s
Sicherheitsgründen zum lokalen Distributor zurückgeschickt werden.
Das Netzteil entsorgen, wenn die Anschlüsse beschädigt sind.
Ÿ
Das Gerät ist für den Gebrauch in sauberer und trockener Umgebung
Ÿ
bestimmt.
Das Gerät muss in der Endapplikation in einem Gehäuse montiert sein.
Ÿ
Die Stromversorgung darf im Betrieb nicht zugänglich sein.
Darauf achten, dass die Temperatur am Tc-Punkt nicht überschritten
Ÿ
wird
Entsorgung
Das Gerät enthält Bestandteile, welche zum Recycling geeignent sind und
Komponenten, welche fachgerecht entsorgt werden müssen. Stellen Sie
daher sicher, dass das Gerät nach Gebrauch korrekt entsorgt wird.
Bauteilbezeichnung
SPEZIFIKATIONEN
TMW 36-
112P
124P
Nominale Eingangsspannung
100 - 240 VAC
Nominaler Eingangsstrom
0.7-0.4A
Eingangsbetriebsspannungbereich
85-264 VAC
Eingangsspannungsfrequenzbereich
47 - 63 Hz
Einschaltstrom (115/230 VAC)
25/50A
Sicherungsnennwert / Charakteristik
6 - 16A / Charakteristik B or C
Max. Ausgangsleistung
36 W
Ausgangsspannung
12 VDC
24 VDC
Max. Ausgangsstrom
3.0 A
1.5 A
Leistungsfaktor λ
0.5
0.5
Typischer Wirkungsgrad (230 VAC )
87%
88%
Betriebstemperaturbereich
- 20°C bis +80°C
Max. Gehäusetemperatur Tc (Fig.1)
93°C
93°C
Ausgangsleistungsminderung - Eingangsspanung
2%/V unterhalb 100VAC
Oberhalb 50°C 2%/K; Vin≥187VAC
Ausgangsleistungsminderung – Temperatur
Oberhalb 40°C 2%/K; Vin<187 VAC
Schutzklasse
Klasse II
Schutzmassnahme (Eingang/Ausgang)
2 x MOPP
Schutzart
IP68
Kriechstrom (max.)
100 µA
Berührungsstrom (max.)
100 µA
Netzstruktur
TN-S, TN-C, TT, IT
Luftfeuchtigkeit
0 - 100%
Lagertemperatur
- 40°C bis +90°C
5000 m/50-106kPa
Maximale Höhe
(3000m - IEC61558-2-8)
Consignes de sécurité et avertissements
FR
!
!
Ne pas ouvrir l'appareil!
Avant toute installation ou action d'entretien, s'assurer que
l'interrupteur principal soit éteint et sécurisé contre toute remise en
marche.
L'appareil peut être installé et mis en service uniquement par du
personnel qualifié.
Ne jamais travailler sur l'appareil, quand il est mis sous tension.
Risque d'arcs et de chocs électriques, qui peuvent provoquer des
blessures corporelles graves, la mort ou des dégâts matériels
importants.
L'appareil doit être branché à l'alimentation dans le respect des
réglementations nationales (par ex. VDE0100 et EN50178).
Toutes les connexions d'entrée et de sortie de la carte de circuit
imprimé doivent être correctement calibrées et doivent être
connectées avec la bonne polarité. Fig.1
Les pistes de la carte de circuit imprimé hôte ne doivent PAS être
acheminées directement sous l'alimentation électrique
Les connexions d'entrée de l'alimentation électrique doivent être
suffisamment protégées par des fusibles.
Ne pas introduire d'objets dans l'appareil.
Tenir à l'écart du feu et de l'eau.
Le fusible interne n'est pas accessible. Si ce fusible interne est grillé, le
bloc d'alimentation présente un défaut interne et, pour des raisons de
sécurité, il doit être expédié au distributeur local.
L'alimentation électrique doit être mise au rebut si les broches sont
endommagées.
L'appareil est conçu pour être utilisé dans un environnement propre et
sec.
L'appareil doit être monté à l'intérieur d'une enceinte dans
l'application finale. Pendant le fonctionnement, le bloc d'alimentation
n'est pas accessible.
Veuillez vérifier que la température au point Tc n'est pas dépassée.
Recyclage
L'appareil contient des éléments appropriés au recyclage et des
composants nécessitant une mise au rebut particulière. L'utilisateur est
donc prié de s'assurer que l'appareil sera recyclé à la fin de sa durée de vie.
Code de commande
SPÉCIFICATIONS
TMW 36-
112P
124P
Tension nominale d 'entrée
100 - 240 VAC
0.7-0.4A
Courant nominal d'entrée
85 - 264 VAC
Plage de tension d'entrée opérationnelle
Plage de fréquence de tension d'entrée
47 - 63 Hz
Courant d'appel (115/230 VAC)
25/50A
6-16 A / caractéristiques du disjoncteur B
Valeur nominale / caractéristiques du disjoncteur
or C
Puissance de sortie maxi
36 W
Tension de sortie
12 VDC
24 VDC
Courant de sortie maxi
3.0 A
1.5 A
Facteur de puissance λ
0.5
0.5
Rendement typique (230 VAC)
87%
88%
Température de fonctionnement
-20°C á +80°C
Température maxi du boîtier Tc (Fig.1)
93°C
93°C
Réduction de la puissance de sortie - Tension d'entrée
2%/V au dessous de 100 VAC
En amont de 50°C 2%/K; Vin≥187VAC
Réduction de la puissance de sortie - Température
En amont de 40°C 2%/K; Vin<187VAC
Classe de protection
Classe II
Moyens de protection (entrée/sortie)
2 x MOPP
Degré de Protection
IP68
Courant de fuite (maxi)
100µA
Courant de contact (maxi)
100µA
Configuration du réseau
TN-S, TN-C, TT, IT
Humidité
0-100%
Température de stockage
-40°C á +90°C
5000 m/50-106kPa
Altitude maximale
(3000m - IEC61558-2-8)
Fig.1
20
20
Tc
Top view
10,3
4,6
13,1
22,2
21,2
17,6
19,8
22,2
7,5
13,1
14,6
I/P
L
N
O/P
+ -
mm
Pin view
P
- V
Fig.3
(O/P)
(I/P)
P/Pmax
[%]
100
90
80
70
60
50
85
100
115
150
200
250
264
V
[VAC]
(I/P)
Specifications can be changed without notice
TMW 36-P
Power Supply Unit for
Home & Office applications
www.tracopower.com/overview/tmw
Fig.2
53.0
1 ±0.1
34.0
O
26.3
3.2
(x2)
3
4.5
+0.5
-0.3
kg
0,13kg
mm
© Copyright 2019 Traco Power Solutions Ltd.
loading

Resumen de contenidos para TRACO POWER TMW 36-P

  • Página 1 5000 m/50-106kPa 5000 m/50-106kPa 5000 m/50-106kPa Altitude maximale Maximum Altitude Maximale Höhe (3000m - IEC61558-2-8) (3000m - IEC61558-2-8) (3000m - IEC61558-2-8) Rev. Oct 19,2020 Doc No.>>TMW-P Installation Instruction>> Specifications can be changed without notice © Copyright 2019 Traco Power Solutions Ltd.
  • Página 2 5000 m/50-106kPa Altitud máxima Altitudine massima Максимальная высота над уровнем моря (3000m - IEC61558-2-8) (3000m - IEC61558-2-8) (3000m - IEC61558-2-8) Rev. Oct 19,2020 Doc No.>>TMW-P Installation Instruction>> Specifications can be changed without notice © Copyright 2019 Traco Power Solutions Ltd.